The menu system
▀
Operation settings
►
Lambda probe
Co2
Use pellets
Emergency mode
Cleaned boiler
Operating time
Time betw. clean
Use pellets
►
Use pellets
Chimney fan
Chimney fan start
Loading pump
Start
Other
►
Date
Time
Calib. sensors
Function test
Alarms
English
Temp sensor
Calibrate sensors
►
Sensor G1
Sensor G2
Sensor G3
Sensor G4
Function test
►
Chimney fan
Sec. damper
Prim. damper
Shunt motor
Radiator pump
Loading pump
Alarms
►
High flue gas
Low flue gas
Ignition
Temp. sensors
►
Effecta AB - Västra Rågdalsvägen 21 - 434 99 Kungsbacka - 0300 - 22320 - info@effecta.se
Activates the lambda sensor.
Settings of Co2 level in combustion.
Menu for using pellets.
Activates when lambda probe is broken, prim. damper 70% and sec. damper 40%
Reset cleaning alarm.
Time that the fan on the boiler has been active.
Countdown to the next cleaning of the boiler.
Activates the use og pellets.
Activates the fan on the boiler.
Setting of the temperature for the fan to start, normally not activated.
Activates the loading pump for pellets use.
Start temperature for the loading pump.
Date settings.
Time settings.
Menu for calibrating sensors.
Menu for function test.
Menu for history of alarms.
Menu for choosing language.
Menu temperature log
Calibration of active sensors. It is important that the outdoor sensor is calibrated correct.
Activates the chimney fan
Open / closes secondary damper
Open / closes primary damper
Open / closes shunt motor
Activates radiator pump
Activates loading pump
Counts the alarms for high flue gases, 610 °F
Counts the alarm for low flue gases,activates when flue gases hasn´t reached 212°F in 60 min.
Counts the times a lambda value hasn´t been reached in 60 min.
Temperature log for the outdoor sensor.
Temperature log for the indoor sensor
Temperature log for the flow temperature
Temperature log for the boiler temperature.
Temperature log for the loading temperatureladdningstem.
NOTE! The log requires that the sensor is connected or function activated.
23