The menu system

OPERATION
Operation settings
Lambda probe
Co2
Use pellets
Emergency mode
Cleaned boiler
Operating time
Time betw. clean.
Use pellets
Use pellets
Chimney fan
Chimney fan start
Loading pump
Start

USB connection

Don´t interrupt the download. This will damage all software in
the boiler. Make sure that your USB-stick contains the correct
files. There should be an *.hex- and *.bin file on the USB stick.
In order to upgrade the software in the boiler you need to connect
a USB-memory to the boiler. There is an connection cable located
behind the cover plate .
Turn off the power to the boiler. Insert the USB-memory, then turn the
power back on. The controller starts downloading the new software.
It´s important not to interrupt the updating
procedure, this will damage the controller. Wait until the picture of
flags comes up on the display.
Disconnect the USB-memory. Your boiler is now updated.
Effecta AB - Västra Rågdalsvägen 21 - 434 99 Kungsbacka - 0300 - 22320 - info@effecta.se
22
1. Flue gas temperature
2. Co2
3. Boiler temperature
4. Primary air
5. Secondary air
System settings
Ja
Shunt group 1
13%
Shunt group 2
Nej
Shunt group 3
Nej
Nej
55h
Shunt group 1 & 3
40h
Program
Room temp
Flow temp
Radiator pump
Nej
Max flow temp.
Nej
Min. flow temp.
85°C
Max room temp.
Nej
Min room temp.
55°C
Heating off
Outdoor temp
Heat curve
Energy saver
Backend prot.
Shunt group 2
Program
Flow temp.
Radiator pump
Cylinder
Energy saver
Energy saver
Lowering temp
Mon
Tue
Wed
Thu
Fri
Sat
Sun
HEATING SYSTEM
>
>
>
Inne
20.0 (18.2)°C
10°C
Ja
60°C
10°C
25°C
15°C
16°C
-8°C
Slope
40°C
Adjustment
0 °C
>
>
Konstant framl
Ja
16°C
- 5 °C
 06 _ _  _ _  22
 06 _ _  _ _  22
 06 _ _  _ _  22
 06 _ _  _ _  22
 06 _ _  _ _  22
 06 _ _  _ _  22
 06 _ _  _ _  22
1. Flow temperture
2. Temp. accumulator top
3. Temp. accumulator bottom
4. Temp. indoor sensor
5. Temp. outdoor sensor
OTHER
Other
Date
>
Time
>
Calib.sensors
>
Function test
>
Alarms
>
English
>
Temp sensor
>
Calibrate sensors
Sensor G1
0°C
0 °C
Sensor G2
Sensor G3
0°C
Sensor G4
0°C
0 °C
Sensor G5
Sensor G6
0°C
Sensor G8
0°C
0 °C
Sensor G8
0 °C
Outdoor
0 °C
Indoor
Function test
Från
Chimney fan
Från
Sec. damper
Från
Prim. damper
Från
Shunt motor(+/-)
Från
Radiator pump
Från
Loading pump
Alarms
High fluegas temp.
0
Low fluegas temp.
0
Ignition
0