The menu system
System settings
Shunt group 1
Shunt group 2
Shunt group 3
Shunt group 1 & 3
Program
Room temp.
Flow temp.
Radiator pump.
Max flow.
Min flow.
Max room temp.
Min room temp.
Heating off
Outdoor temp.
Heat curve
Slope
Adjustment
Energy saver
Backend prot.
Shunt group 2
Program
Flow temp.
Radiator pump
Cylinder
Energy saver
Energy saver
Lowering temp.
Mon
 06 _ _  _ _  22
Tue
 06 12  16  22
Alarms at disruption
Alarm
High flue gas
Alarm
Low flue gas
Alarm
Ignition
Alarm
Room temp.
Alarm
Outdoor temp.
Effecta AB - Västra Rågdalsvägen 21 - 434 99 Kungsbacka - 0300 - 22320 - info@effecta.se
24
>
Selection of shunt group.
>
Selection of shunt group.
>
Selection of shunt group.
Selection of sensor control. (Indoor-Outdoor-Both-Constant)
Shows room temp.
Shows flow temp.
Activates radiator pump.
Maximum allowed temperature to the flow.
Minimum allowed flow temp.
Maximum allowed room temp.
Minimum allowed room temp. Shunt opens full at set temp.
Outdoor temp when heating turns off. Rad. pump is runned 1min/2hours.
Outdoor temperature at the outdoor sensor
The outdoor sensors heat curve (pg.19-21).
The outdoor sensors slope (pg.19-21.).
The outdoor sensors adjustment(pg.19-21.).
Options for the energy saver.
>
Selection of sensor control.
Shows flow temp.
Activates radiator pump.
>
Options for the energy saver.
- 5 °C
Weekly Schedule when the indoor temperature is lowered by a number of degrees.
Note that a underfloor system reacts slower than a radiator system.
Example: At 06 returns to normal temperature and to be lowered again at 22.
Example: At 06 returns to normal, lowered at12 and at 16 returns to normal
again and lowered at 22.
The flue gas temperature has been over 608°F, which normally means a heavy sooted boiler
or poor combustion. The flue gas sensor can also be broken and we recommend that you
contact your installer.
The flue gases has failed to reach 212°F after 60 minutes of operation.
A value for the lambda probe is not reach after 60minuts of operation.
Room sensor activated but not connected.
Room sensor activated but the flow sensor(G7) is not connected.
Outdoor sensor activated but not connected.
Outdoor sensor activated but the flow sensor(G7) is not connected.