5-11.

Sequencer Controls (DX, LX And All CE Models)

3
4
Or
1
2
Or
1
Sequencer Control
Sequencing is available while using
the TIG process, but is disabled if a
remote foot or finger current control
is connected to the Remote recep-
tacle while in the RMT STD mode.
Press switch pad until desired pa-
rameter LED is illuminated.
2
Encoder Control (Set Value)
3
Ammeter (Displays Value)
See Section 5-17 for all Sequencer
parameter ranges.
INITIAL A (Initial Amperage) - Use
control to select a starting amper-
age that is different from the weld
amperage.
Application:
Initial Amperage can be used to as-
sist in preheating cold material prior
to depositing filler material, or to en-
sure a soft start.
INITIAL t (Initial Time)(LX Models
Only) - Press control again and turn
Encoder to set amount of time
needed at the beginning of the weld.
INITIAL SLOPE t (Initial Slope
Time) Use control to set amount of
time that it takes to slope from initial
amperage to weld amperage. To
disable, set to 0.
4
Amperage Switch Pad
Weld Time (LX Models Only) -
Press Amperage switch pad twice.
Set desired weld time.
FINAL SLOPE t (Final Slope Time)
- Use control to set amount of time
it takes to slope from weld amper-
age to final amperage. To disable,
set to 0.
Application:
Final Slope should be used while
welding materials that are crack
sensitive, and/or to eliminate the
crater at the end of the weld.
FINAL A (Final Amperage) - Used
to set amperage to which weld am-
perage slopes to.
FINAL t (Final Time)(LX Models
Only) - Press control again and turn
Encoder to set Final Amperage
time.