BMC Message on Lower LCD Line
Processor Thermal Trip (X: 1 or 2)
Insufficient Cooling Error (Not
Power ON)
DUMP Request !
Processor Missing
CPU1_DIMMX Uncorrectable Error
(X: number)
CPU2_DIMMX Uncorrectable Error
(X: number)
ProcessorX Internal Error (X: 1 or
2)
Sensor Failure Detected.
SMI timeout
IPMI Watchdog timer timeout
IPMI Watchdog timer timeout
(Power off)
Mezzanine Card1 Power Fault
Mezzanine Card2 Power Fault
Drive X Fault (X: number)
144
Cause
The power was forcibly turned off
due to a CPU temperature
abnormality.
In the Blade Enclosure, the
number of fans installed is
insufficient or the installed fan is
faulty. Thus, the CPU blade failed
to power on due to insufficient
cooling power.
DUMP switch is pressed.
No CPU is installed in CPU #1
socket.
An uncorrectable error occurred
on DIMM for CPU #1. X: Failed
DIMM number (1-origin)
An uncorrectable error occurred
on DIMM for CPU #2. X: Failed
DIMM number (1-origin)
An internal CPU error (IERR)
occurred.
Abnormality in a sensor was
detected.
A timeout occurred while
servicing system management
interrupts.
A watchdog timer timeout
occurred.
An error occurred on power
supply circuit of mezzanine card
installed in Type 1 mezzanine
card slot of CPU blade.
An error occurred on power
supply circuit of mezzanine card
installed in Type 2 mezzanine
card slot of CPU blade.
A failure was detected on disk
drive installed in CPU blade.
X: Disk drive number (0-origin)
Express5800/B120e-h Maintenance Guide
Solution
It is possible that a fan has failed or is
clogged. Contact your sales representative
and request repairs. Check if fans in Blade
Enclosure work normally. Refer to the User's
Guide of the Blade Enclosure to make sure
that the sufficient number of fans are
installed, and CPU blades and fan units are
installed in correct locations. Check
installation status of heat sink of the CPU
blade. Check if ambient temperature of
installation location satisfies the operation
guarantee condition. If this does not resolve
the problem, contact your sales
representative.
Wait until completion of memory dump
process.
Check installation status of the CPU blade. If
this does not resolve the problem, contact
your sales representative.
Contact your sales representative.
Check installation status of the failed
mezzanine card. If this does not resolve the
problem, contact your sales representative.
Contact your sales representative.