NEC Express5800 Series Maintenance Manual page 143

Hide thumbs Also See for Express5800 Series:
Table of Contents

Advertisement

Chapter 3 Appendix
Messages displayed on a lower LCD line
BMC Message on Lower LCD Line
ProcessorX Voltage Lower
Non-Critical (X: 1 or 2)
ProcessorX Voltage Upper
Non-Critical (X: 1 or 2)
ProcessorX Voltage Lower Critical
(X: 1 or 2)
ProcessorX Voltage Upper Critical
(X: 1 or 2)
BaseBoard Voltage Lower
Non-Critical
BaseBoard Voltage Upper
Non-Critical
BaseBoard Voltage Lower Critical
BaseBoard Voltage Upper Critical
VBAT Lower Non-Critical
VBAT Upper Non-Critical
VBAT Lower Critical
VBAT Upper Critical
Baseboard Temperature1 Lower
Non-Critical
Baseboard Temperature1 Upper
Non-Critical
Baseboard Temperature1 Lower
Critical
Baseboard Temperature1 Upper
Critical
CPUX_DIMM Area Temperature
Upper Non-Critical (X: 1 or 2)
CPUX_DIMM Area Temperature
Upper Critical (X: 1 or 2)
ProcessorX Thermal Control Upper
Non-Critical (X: 1 or 2)
Processor Thermal Control Upper
Critical (X: 1 or 2)
Cause
A voltage abnormality was
detected.
A temperature abnormality was
detected.
Express5800/B120e-h Maintenance Guide
Solution
Contact your sales representative.
It is possible that a fan has failed or is
clogged. Contact your sales representative
and request repairs. Check if fans in Blade
Enclosure work normally. Refer to the User's
Guide of the Blade Enclosure to make sure
that the sufficient number of fans are
installed, and CPU blades and fan units are
installed in correct locations. Check
installation status of heat sink of the CPU
blade. Check if ambient temperature of
installation location satisfies the operation
guarantee condition. If this does not resolve
the problem, contact your sales
representative.
1. POST Error Message
143