Endress+Hauser Levelflex FMP53 Operating Instructions Manual page 152

Guided level-radar
Hide thumbs Also See for Levelflex FMP53:
Table of Contents

Advertisement

Description of device parameters (operating menu)
Navigation
Conditions
Description
Display
Launch signal
Navigation
Condition
Description
Display
152
Diagnostics ® Device check ® Level signal
Only visible if a device check has been performed.
Displays the result of the device check for the level signal.
• Check not done
• Check not ok
Check the mounting position of the device and the dielectric constant of the medium.
• Check ok
Diagnostics ® Device check ® Launch signal
Only visible if a device check has been performed.
Displays the result of the device check for the launch signal (fiducial).
• Check not done
• Check not ok
Check the mounting position of the device. In non-metallic vessels use a metal plate or a metal
flange.
• Check ok