Technical Information
1
Technical Data
Suds container
Table 030-1: Technical Data: Suds Container, Drum, Bearing, Heater Element
Temperature (°F) Resistance (kΩ)
32
41
50
59
68
77
86
95
104
113
122
131
140
149
158
167
176
185
194
199
203
212
Table 030-2: Suds NTC (R30) Resistance Values
2
Function
2.1
Foam Sensing
2.1.1
Foam When Heating During the Main Wash Cycle
Heating the suds generates foam; as foam pushes into the vents, the
pressure increases in the suds container.
If the imbalance sensor registers a pressure increase of 2.4" wc above wash
Moving component
Drum
Drum diameter
Capacity, dry laundry
Drum volume
Fill hole
Drum light
38.0
29.7
23.4
18.6
14.9
12.0
9.7
9.0
6.6
5.4
4.5
3.8
3.2
2.7
2.3
2.0
1.7
1.5
1.3
1.2
1.09
1.06
22
Non-metal suds container, drum
incline 8°
Honeycomb drum
19" (480mm)
8 kg
21 gal (80 L)
15 ¾" (400mm)
LED, 3.4V/1W
W 48xx