Miele W 4802 Technical Information page 67

Us models
Table of Contents

Advertisement

W 48xx
To start a service function: Press Start.
Note:
The component test switches off automatically 30 minutes after the last
component is activated.
Service function
Software status
Check fault memory
2
delete
Option
"Buzzer"
LED
Short
Program index: ID of the power
electronic (ELP), ID of the control
-
electronic (EW)
F 0, No fault; refer to Section 070-
3.11.
F 1, Water/heater NTC short
circuit; refer to Section 070-3.12.
F 2, Water/heater NTC open
circuit; refer to Section 070-3.13.
F 10, Water intake fault (cold);
refer to Section 070-3.14.
F 11, Water drain; refer to Section
070-3.15.
F 15, Water intake fault (hot);
refer to Section 070-3.16.
F 16, Oversudsing; refer to
1
Section 070-3.17.
and
F 19, Sluggish flow meter; refer to
Section 070-3.18.
F 20, Heater (temperature in
1
thermostop not reached); refer to
Section 070-3.19.
F 34, Door does not lock; refer to
Section 070-3.20.
F 35, Door lock does not release;
refer to Section 070-3.21.
F 41, Faulty EEPROM/faulty data;
refer to Section 070-3.23.
F 43, Appliance model not
programmed; refer to Section
070-3.24.
F 44, Faulty I
refer to Section 070-3.25.
F 45, Flash; refer to Section 070-
3.26.
F 46, Display; refer to Section
070-3.27.
67
Technical Information
"Prewash"
Long
X
-
-
-
1
1
1
1
1
2
3
3
4
4
2
C bus connection;
4
4
4
LED
Short
Y
-
1
2
-
1
5
6
9
-
4
5
1
3
4
5
6

Advertisement

Table of Contents
loading

This manual is also suitable for:

W 4840W 4842W 4800

Table of Contents