Technical data
Height
Width
Depth
Useable cabinet dimensions:
Height
Width
Depth
Net weight including plinth and top-box panelling
Net weight including EL/S, DU, SC, CT *
Operating weight
Distributed load (max. load-bearing capacity)
Voltage, rated load, fuse rating
Compressed air connection:
Technical to ISO 8673-1: Class 4
Steam connection (optional):
Quality
Steam pressure
Water temperature of water connection:
Cold water/steam condenser
Hot water/DI water
Water connection pressure
Operating conditions:
Ambient temperature
Relative humidity
Minimum
Maximum for temperatures up to 31 °C
Linear decreasing for temperatures up to 40 °C
Storage and transportation conditions:
Ambient temperature
Relative humidity
Air pressure
Max. altitude above sea level
Protection category (according to IEC 60529)
Degree of soiling (according to IEC/EN 61010-1)
Overvoltage category (according to IEC 60664)
Sound pressure level LpA during cleaning and drying
Test certifications
marking
Manufacturer address
* See the installation plan for optional extras
*** If installed above 1500 m, the boiling point of the wash water will be lower. In this case, the disinfection temperature
and the holding time might need to be adjusted.
82
2495
mm
1150
mm
990
mm
675
mm
650
mm
800
mm
477
kg
667
kg
902
kg
2
7.8
kN/m
See data plate
600-800
kPa
Dry industrial steam
250-1000
kPa
5–20 °C
5–65 °C
200–1000 kPa
5–40 °C
10 %
80 %
50 %
-20 to +60 °C
10–85 %
500–1060 hPa
2000 m**
IP 20
P2
II
<65 dB(A) re 20 µPa
VDE, radio and television suppressed
2006/42/EC Machinery Directive
Miele & Cie. KG, Carl-Miele-Str. 29, 33332 Gütersloh,
Germany