f)

Motor Test

1) Remove the connecti ng leads from the starter's C terminal
and connect them directly to the battery's posi tive
termi nal. Then con nect the battery's negati ve term inal to
the starter body.
2) If the starter ru ns n ormall y, the magnet switch is defec-
tive; if not, the motor is defective.
(A) Electrical connections for motor test
(a)
Starter
C022F073
C0
22F057

Magnet Switch

(1) Pull-In Coil (Attraction Test)
1) Appl y 1/2 the rated vol tage (approx. 6V) across the S
termi n al and C termi nal .
2) I f the pl u nger is attracted strongl y , the pul l -i n coi l is good;
if not, it is defecti ve.
86
(c)
B
terminal
KiSC issued 09, 2007 A