0
Grounding of Armature Coil
1 ) Check
conduction
a rmatu re shaft.
2)
I f cond ucti n g, repl ace.
0
Checking Armature Flexure
1) Measu re the amoun t of flexu re; i f the measu remen t
exceeds the reference val ue, replace. Caref ul l y check to
see if the core is scratched.
C,
Checking Armature Coil Short-Circuited
1) Set the armature on the
armatu re whi le touch i n g it wi th steel piece.
2) I f the steel piece starts to vi brate or to be attracted some-
where on the armatu re, this suggests that the coi l contains
a l ayer short at that poi n t.
3) I f faul ty, repl ace.
@
Checking Field Coil Breakage
1) ) To check cond uction , pl ace the tester probes onto
the lead and b rush .
2)
I f either are n ot cond ucti ng, replace.
93
across
the
com mutator
ar matu re
tester.
Rotate
KiSC issued 09, 2007 A
and
the
the