Table 3. POST error messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, "Parts listing," on page 65 to determine which components are customer replaceable units
(CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Error code
Description
301 and 303
An error occurred during the keyboard and
keyboard controller test. These error
messages also might be accompanied by
continuous beeping.
602
An invalid diskette boot record error
occurred.
604
An error occurred during a diskette drive
test.
962
A parallel port configuration error occurred.
Action
1. If you just connected a new mouse or other
pointing device, turn off the computer and
disconnect that device. Wait at least 5 seconds;
then, turn on the computer. If the error message
goes away, replace the device.
2. Make sure that nothing is resting on the keyboard
or pressing on a key.
3. Make sure that no key is stuck.
4. Reseat the keyboard cable and make sure that it is
connected to the correct connector on the
computer.
5. After installing a USB keyboard, run the
Configuration/Setup Utility program to enable
keyboardless operation and prevent the POST
error message from being displayed during startup.
6. Run the diagnostic tests to isolate the computer
component that failed.
7. Replace the following components one at a time,
in the order shown, restarting the computer each
time:
a. Keyboard
b. (Trained service technician only) System board
1. Reseat the diskette drive cable.
2. Replace the following components one at a time,
in the order shown, restarting the computer each
time:
a. Diskette drive cable
b. Diskette drive
c. (Trained service technician only) System board
1. Make sure that the Configuration/Setup Utility
program correctly reflects the type of diskette drive
that is installed.
2. Reseat the diskette drive cable.
3. Replace the following components one at a time,
in the order shown, restarting the computer each
time:
a. Diskette drive cable
b. Diskette drive
c. (Trained service technician only) System board
1. If you changed a hardware option, make sure that
the parallel port setting is correct in the
Configuration/Setup Utility program. If the setting is
not correct, change it and save the settings.
2. (Trained service technician only) Replace the
system board.
21
Chapter 2. Diagnostics