4018M
4.4.3 Analog Input Data Logger Command Set
Command Syntax
@AACCCSDMTTTT
@AAD
@AASO
@AAT
@AAL
@AAN
@AARNNNN
@AAACSDHHHHTEIIII
@AABC
Command
Name
Set Memory
Set the channel storage
Configuration
status, standalone mode, data
logger mode, storage type and
sampling interval for the
specified analog input data
logger.
Read Memory
Return the configuration
Configuration
parameters for the specified
analog input data logger.
Set Memory
Start/stop the recording
Operation
function of the memory
Mode
module.
Read Memory
Read the recording status of
Operation
the memory module.
Mode
Event Record
Read the number of stored
Count
event records in the memory
module.
Standard
Read the number of stored
Record Count
standard records in the
memory module.
Read Record
Read the contents of the
Content
specified record.
Set Alarm Limit Set the high/low alarm
settings for the specified
channel.
Read Alarm
Read the high/low alarm
Limit
settings for the specified
channel.
Description
Chapter 4 Command Set
4
Chapter
I/O Module
4018M
4018M
4018M
4018M
4018M
4018M
4018M
4018M
4018M
4-