Figure 17.Euro Connector Installed - ADTRAN Total Access 300 Series Installation And Maintenance Manual

Hide thumbs Also See for Total Access 300 Series:
Table of Contents

Advertisement

Total Access 300 GigE SFU ONT Installation and Maintenance Guide
6. Loosen each retaining screw and insert the wire into the appropriate slot (see Figure 14 on 
7. Tighten the retaining screws.
8. Reinstall the Euro‐Connector in the Electronics Module.
Back of Electronics Module
9. Tie wrap and route these wires as shown above. This will prevent the connector from 
10.Reinstall the rubber grommet when closing the Electronics Module. 
28
page 26 and Table
6 on page 26).
Rubber Grommet
Figure 17. Euro Connector Installed
coming loose when the Electronics Module is closed.
7
6
5
4
3
2
1
Euro-Connector
Tie Wrap wires as shown
Note: Even though there are brackets to
position the Euro-Connector wires,
their use is not recommended. Use
of these brackets can "bind" the wires
when the Electronics Module is closed.