Grounding the Buried Fiber

The buried fiber drop cable to the subscriber's premise used in this application can be one of 
the following:
• Non‐armored: the non‐armored fiber drop cable has a metal strand for locating purposes. 
• Armored drop: when the fiber drop cable is armored, grounding of the cable sheath is 

Ground Wire Connection

!
WARNING
Extreme care must be taken when attaching the ground connectors to the
utility (earth) ground rod. If the ground is interrupted or disturbed in any
way, an unsafe condition will exist. Refer to the National Electrical Code
(NEC) and state/local codes for details on grounding requirements.
Complete the ground connection by completing the following steps:
1.Remove the rubber grommet from the housing (see Step 1 in Figure 12).
2. Insert a 6 AWG solid copper ground wire through the rubber grommet (see Step 2 in 
3. Reinsert the rubber grommet with the ground wire back in the ONT housing (see Step 3 in 
4. Ensure the ground wire is routed as shown in Figure 13 on page 24. 
6418770XGX-5B
Skip this procedure if the fiber drop is non‐armored.
required at the ONT. A UL Listed ground shield connector is utilized to ground the 
armored fiber. If the fiber drop is armored, complete the following to ground the fiber:
1.Install the ground shield connector assembly on the fiber drop cable.
2.Place black electrical tape tightly around the connections to prevent water intrusion and 
corrosion.
3.Attach a ground strap to the ground termination lug 
Figure 12). Terminate the ground wire at the ground bar as shown in Figure 13 on page 24.
1
Figure 12. Cable Ground Installation
Figure 12). 
2
Installation
3
23