Total Access 300 GigE SFU ONT Installation and Maintenance Guide
!
WARNING
The 10/100/1000Base‐T port(s) and POTS are classified as Type 4 as defined in
Appendix B of GR‐1089‐CORE, Issue 4, and is suitable for connection to intra‐
building or unexposed wiring or cabling only. Do not metallically connect
these ports to interfaces which connect to the Outside Plant (OSP) or to the
OSP wiring. The 10/100/1000Base‐T ports and POTS are designed for use as
an intra‐building interface only (Type 4 ports as described in GR‐1089‐CORE,
Issue 4) and require isolation from exposed OSP cabling. The addition of
Primary Protectors is not sufficient protection in order to connect this
interface metallically to OSP wiring.
C
CAUTION
This product contains a Class 1 Laser module which complies with 21 CFR
1040.10 and 1040.11.
!
CAUTION
•  This equipment must be connected to a known, reliable earth ground at all
times during installation and service. Refer to the National Electrical Code
(NEC) and state/local codes for details on grounding requirements. A 6
AWG copper ground conductor shall be used to connect the equipment to
earth ground.
•  Per GR‐1089‐CORE the Total Access 300 Series SFU ONTs are designed and
intended for installation as part of a Common Bonding Network (CBN).
The Total Access 300 Series SFU ONT are not designed nor intended for
installation as part of an Isolated Bonding Network (IBN).
•  Per GR‐1089‐CORE Section 9, the SFU ONTs do not have an internal DC
connection between 12V and frame ground. 
•  The Total Access 351 & 352 SFU ONT chassis frame ground terminal must
be connected to an earth ground to ensure the ONT SFU is properly
grounded.
NOTE
•  The main feed is optical and therefore not classified as any type of port as
defined in Appendix B of GR‐1089‐CORE, Issue 4.
•  The Total Access 300 Series SFU ONTs are designed to operate with
nominal operating voltage of 12 VDC and a minimum operating voltage of
10.5 VDC. The Total Access 300 Series will not be damaged by any steady
state voltage between 10.5 VDC and 15.0 VDC in magnitude.
6
Table 5. Configuration Codes
Configuration Codes
Power Code (PC)
Telecommunication Code (TC)
Installation Code (IC)
Input
Output
F
C
A
6418770XGX-5B