Status
27
Power Supply Input Voltage
29
Lens ID
30
Main Control Board
32
Power Supply Output Voltage
46
Status LED Board
47
Side Panel NFCT
50
Formatter-Red
51
Formatter-Green
52
Formatter-Blue
Christie TruLife+ Technical Reference–Status System
020-103327-03 Rev. 1 (04-2021)
Copyright
©
2021 Christie Digital Systems USA, Inc. All rights reserved.
State
Value
OK
AC Input Low
AC Input Failure
Detected
Unknown
Not Detected
OK
Unknown
Initialization Fault
<value>V
OK
Unknown
Communication Fault
OK
Unknown
Not Detected
Off
OK
Christie TruLife+ status system
Description
The power supply input voltage is OK.
Displayed when the AC input is less than
180 VAC.
Displayed when the AC input is less than
85 VAC or the power is completely lost.
Detected the lens.
Cannot determine the state of the lens
as the communication path to the lens is
not working.
Cannot detect the lens.
The main control board has been
initialized at least once and is known to
be OK.
Cannot determine the main control
board status because it has not been
powered up.
Cannot successfully program the main
control board.
Displays the output voltage from the
power supply. This value is typically 54V.
The status of the status LED board (SLB)
is OK.
Cannot determine the status of the
status LED board (SLB) because the
backpane (C4BP) is nonfunctional.
Cannot communicate with the status LED
board (SLB).
The side panel NFCT is OK.
The side panel NFCT status is unknown
because the integrated keypad board
(IKB) is non-functional.
Cannot detect the side panel NFCT.
The formatter is in standby without any
cached errors or warnings.
Properly detected and initialized the
formatter.
8