Satel TR49 Integration Manual page 15

Transceiver module
Hide thumbs Also See for TR49:
Table of Contents

Advertisement

Carrier power
stability
Electrical Interface
Interface Connector
Data speed of Serial
interface
Data speed of Radio Air
Interface
Air Interface Encryption
Data Format
Modulation
Operating voltage
Current consumption in
Power Save mode
Typical Power
Consumption
410...475 MHz
Inrush Current, power
turned ON
3
Temperature Range
Temperature Ranges
Vibration
ESD
4
Antenna Connector
Construction
Size L x W x T
Weight
Test condition ��
= 4.0 V and ��
����
According to EN 300 113 V2.2.1 measurement setup.
1
Measured using Agilent 1147B current probe and TTi TSX1820P DC power supply.
3
DATA MODULE
CMOS-UART Inputs and outputs referred to
IO Voltage processed by user (1.8-3.3V) RTS,
CTS, RX, TX, +VCC, GND
1.27 mm pitch socket
9600 – 115200 bps
4FSK FEC OFF / ON:
19200 / 14400 bps (25 kHz)
9600 / 7200 bps (12.5 kHz)
AES128
Asynchronous data
GMSK, 4-GFSK
GENERAL
+3.7...+5.5 VDC
< 2 mA
440 mW
SLEEP1: TBD mW
4.8 W @ 1000 mW RF out
< 12 A, duration < 50 µs
-20 °C ...+55 °C
-40 °C ...+70 °C
-40 °C ...+85 °C
≤ 25g
± 10 kV
± 8 kV
50 Ω, HIROSE U.FL compatible
PWB with sheet metal EMI shields
57 x 36 x 6.9 mm
20 g
= 25 °C
��
14
Integration Guide, V 1.7
< ±1.5 dB
Samtec 20-pin through
hole, CLP-110-02-L-D-K-TR
ENA_MOD set to LOW
RX-mode
RX-mode
TX-mode,
Continuous, 50 Ω
RX-mode
Type Approval conditions
Functional
Storage
100 Hz≤f
≤2,0 kHz (over 90 %
vibration
packet success ratio)
Antenna connector. Acc. to
EN61000-4-2; 150pF/330Ω
DTE connector. Acc. to EN61000-4-
2; 150pF/330Ω
I-PEX 20279-001 -E-01
SATEL-TR49

Advertisement

Table of Contents
loading

Table of Contents