7.
Place the BED LIFT CONTROL switch (Fig. 26) over the hole and secure it with the screws provided.
Make sure the switch is positioned such that both screws will securely hold the switch in place.
Relay Control Module
All outputs are marked on underside of the relay control module (Fig. 27).
Wiring Diagram
RVIA wiring requirements restrict the length of exposed motor leads to a maximum of 10" (254 mm).
Therefore, the Relay Control Module must be placed above the motor or on the wall of the unit in close
enough proximity to the motor that the 10" (254 mm) motor lead will reach.
Brake
To
Motor
RELAY CONTROL MODULE
3-pin
To Upper
Limit Switch
Rev: 10.22.19
A
B
To
(Top View)
2-pin
To Lower
Limit Switch
Fig. 26
Switch Mounting
Screws
Fig. 27
RJ-11 Communication
Cable
NOTE: RJ-11 cable must be straight
Page 14
Power Pigtail
supplied with Relay
Control Module
Butt
Connectors
10 AWG
}
+12V DC
(2.59 mm)
stranded
electrical wire
from power
Ground
through cable — standard
telephone cable will not work.
source
CCD-0001541