Webasto AT2000STC Installation Manual page 6

Table of Contents

Advertisement

Webasto Air Top Installation Guide – AT2000STC 
 
2.4 The combustion air inlet (Fig 3) (3) has a slot to accommodate the wires, ensure the fuel pump wires sit 
neatly in this slot. Never run the wires through the combustion air inlet tube as it will create air restrictions.  
                                                   
 
 
2.5 Attaching combustion air tube. A matching slot needs to be cut in one end of the combustion air tube to 
accommodate the fuel pump wires. 
 
 
 
Fig 9 – Combustion Air Tube "V" cut. 
 
2.6 Using the 25mm hose clamp, fix the combustion air tube to the inlet (Fig 3) (3).  
Note: Ensure that the hose clamp & fuel pump wires are not rubbing. 
 
Under no circumstance may the combustion air be taken from areas occupied by people. The combustion air intake 
opening must not point in the direction of travel. It must be located so that it cannot become clogged with dirt or 
road debris. 
The combustion air must be extracted using a combustion air tube supplied in the kit and protected from dust and 
water ingress. 
Air Top 2000STC Installation Guide 2020 | Webasto Thermo & Comfort Australia Pty Ltd. 
 
Fig 8 
             
Fig 9a – Combustion Air Filter 
 
                               