Grease the bottom part of the telescopic KESSEL attach-
ment piece with lubricant and place into the tank opening,
bring into the desired position and fasten by means of a
clamping ring. Alternatively, it is also possible to apply lubri-
cant to the sealing ring. With the aid of the existing clamping
ring it is now possible to fasten the attachment piece in the
desired position (alignment with the top ground surface). The
fine adjustment to the final height is then effected with the
adjusting screws. A ground slope can be compensated for
 
Inlet
4.10 Concluding filling of the tank.
Before starting to backfill, check once again the inlet and drain line as well as the ventilation line and the cable conduit.
Align the attachment piece with the top ground surface.
4. Installation and assembly
The sealing lips could point downwards on
the inside of the ring.
with the continuously height-adjustable and up to 5° inclin-
able attachment piece. The "Innofant" labels included in the
supply must be attached to the cleaned and dry surface on
the attachment piece (see illustration).
Important: The green "Innofant" must be placed on the inlet
side and the red one on the drain side!
The attachment piece must afterwards be sufficiently back-
filled and compacted.