Sleeping Mode
The device is on and in the
network
The device is on but not in
the network
Low Voltage Warning
Low Voltage

5. Data Report

The device will immediately send a version packet report and a data report including voltage.
The device sends data according to the default configuration before any other configuring.
Default Setting:
MaxTime: Max Interval = 60 min =3600s
MinTime: Max Interval = 60min = 3600s
Reportchange: BatteryVoltageChange = 0x01 (0.1v)
Note:
1. The cycle of the device sending the data report is according to the default.
2. The interval between two reports must be the MinTime.
Please refer Netvox LoRaWAN Application Command document and Netvox Lora Command Resolver
http://www.netvox.com.cn:8888/page/index
Data report configuration and sending period are as following:
Min Interval
(Unit: second)
Any number between
1~65535
Sleeping period: Min Interval
When the reportchange exceeds setting value or the state changes, the device send a data
report according to Min Interval.
1. Suggest to remove batteries if the device is not used
2. Suggest to check device verification on gateway
3.2V
to resolve uplink data.
Max Interval
(Unit: second)
Any number between
1~65535
Reportable Change
Reportable Change
Can not be 0
5
Current Change<
Current Change≥
Reportable Change
Report
per Min Interval
Report
per Max Interval