Technical Data; Electrical Connections - Culligan MP97 Manual

Table of Contents

Advertisement

Available languages

Available languages

TECHNICAL DATA

Power supply :
Climatic conditions :
Display :
Inputs :
pH / redox :
Residual chlorine meter :
Normalized inputs :
Conductivity :
Temperature :
Relay outputs :
Current outputs :
MAIN TECHNICAL NOTES
1.
The absence of trimmers on the front panel for settings increases the protection level.
2.
Output relays directly configurable as to set-point, maximum and minimum alarms. With or without timings.
3.
N° two current outputs, therefore the possibility to register and make proportional regulations with the same
instrument.
4.
Automatic compensation of temperature variations via PT100 in the pH version, via NTC10K in the
conductivity version.
5.
Can be easily reconfigured (even in the field without need to calibrate): from pH-meter to redox meter,
scale change in conductivity meter.
6.
Alarms and errors (diagnostics) visualized directly on display.
7.
Saving of program data / calibration on non-volatile memory (data retention for at 10 years minimum).
8.
Possible acquisition and linearization of non-standard signals on client specification.
9.
The µP 97's software currently manages the following types of instrument :
0 = normalized input
1 = pH-meter
2 = redox meter
3 = residual chlorine meter
4 = thermometer
This data is set during production of the instrument and can only be modified by qualified personnel (the
instrument's software can be preset but the hardware cannot). It is only possible to make changes between the
same types of instrument without re-calibrating (i.e. between different conductivity meters and between pH and
redox). Other instruments are available, e.g. differential inputs. For special versions please contact us.

ELECTRICAL CONNECTIONS

Unless otherwise indicated, the terminals are numbered from 1 to 11.
M003-23 - Rev. 03 - 05/2009
220 V~, 110 V~ , 24 V~ +/- 10% 50-60 Hz 7 VA
Stockage temperature
Working temperature
Max. humidity
High efficiency, 4 digit, red LED h = 12.5 mm
Precision better than 0.3% on F.S.
Repeatability better than 0.2% on F.S.
On insulated terminal strip. Input impedence > 10^12
On terminal strip. For copper-gold cell plus shield. Standard CLE01D.
On extractable terminal strip.
On extractable terminal strip. For 2-electrode cell + shield.
On 3-pin extractable terminal strip. Directly from 3-wire Pt100.
N° 2 independent. On 4-pin extractable terminal strip.
Max. load on contacts: 250 VAC 3 A resistive .
N° 2 , 0/20 or 4/20 mA (program selectable) on 700  max. load.
Max. error : 0.2% on F.S.
K1
SUPPLY
L
N
1 2 3
4 5 6 7
Microprocessore µP97
-20...+60 °C
-10...+50 °C
90% without condensation
7 = conductivity meter with F.S. 2.000
8 = conductivity meter with F.S. 20.00
9 = conductivity meter with F.S. 200.0
10 = conductivity meter with F.S. 2000
OUT mA
K2
1
2
8 9
10
11
4