Menu Code 80 (Valve Cycle Time) - Bennett Natural Gas Series Operator's Manual

Table of Contents

Advertisement

How to Program the Dispenser for Operation
This Menu Code is used to manually trigger the solenoid valves in the upper cabinet.
NOTE: If the dispenser is programmed in Mode 7 for LNG the following options will be available.
All valves start in the OFF position (OFF):
1 = Activates the Recirculation Valve (1A)
2 = Activates the Fill Valve (1B)
3 = Activates the Vent Valve (1C)
4 = Activates all valves (1 ALL)
NOTE: Valves in the hydraulic cabinet will not actuate unless the dispenser is supplied with
pressurized air line.
NOTE: If the dispenser is programmed in Mode 7 for CNG the following options will be available.
1 = Activates Low bank or fill valve in a one bank dispenser.
2 = Activates the mid bank valve
3 = Activates the high bank valve
4 = Activates all valves on side one
5= Activates Low bank or fill valve in a one bank dispenser.
6= Activates the mid bank valve
7= Activates the high bank valve
8= Activates all valves on side two
9 = Activates all fill valves and access valves (CNG 1-Sided,
2-Hoses Only)
Limit Switch statuses (If present) will appear as follows:
C= Closed
O= Open
Blank = Neither open or closed
Dash = Both open and Closed
Blank and Dash = There is an issue.
To test the valves in mode 80, follow this procedure:
1. After the Manager's Mode has been accessed, press
the number 8 and 0, then the MODE button on the
keypad (see figure 80.1).
2. To perform the test on the specific valve press the 1, 2
or 4 button on the Manager's Keypad then ENTER. At
this point the display will show which valve is actuated
(see figure 80.2).
Once the specific valve turns on there should be a
sound heard from the valve. This will indicate that the
valve is operating once the signal is sent from the CPU
Board.
3. Press the CANCEL button to exit this menu code.
NOTE: This mode is for testing purposes. Once the
mode is canceled the valves will automatically close
and return to normal operation.
How to set the Cycle Time for the Valves
Menu Code 80
51
ValVes
COdE
80
ValVes
COdE
80
123919 Rev C 5-17-18
off
Figure 80.1
1A
Figure 80.2

Advertisement

Table of Contents
loading

Table of Contents