4
On the header shield, bend the two tabs downward approximately 90 degrees. Set the header
shield onto the standoffs with the 90° bend facing the pipe shield. The tips of the standoffs will
protrude through the heat shield. Attach the heat shield to the standoffs by aligning the holes on
the heat shield tabs with the holes in the header standoffs and secure using the included screws
5
When finished the fireplace should be configured like the picture below.
© Travis Industries
Installation
Bend tabs
down 90°
Align holes
(for qualified installers only)
12/17/20 - 1528