3.28 Tying down the machine

H
H
Fig. 66: Tying down the machine

3.29 Battery master switch

5001
A
B
C
Fig. 67: Battery master switch
3-42
Important
Possible injury or equipment damage from improper tie-down procedure.
Read the safety instructions at the beginning of this chapter and follow any
other local safety regulations regarding tie-down of the machine.
• Secure the wheels of the dumper at the front, rear and at the sides.
• Firmly strap down the dumper at the eye hooks H onto the platform, with belts or
chainsof adequate size.
• Make sure the driver of the transport vehicle knows the overall height, width and
weight of his vehicle (including the dumper) before transporting, and the legal
transport regulations of the country or countries in which transport will take place!
H
The battery master switch is located under the engine cover. The battery master switch is
located behind the right-hand side maintenance flap on machines equipped with an
optional cab.
Important
Do not disconnect the battery while the engine is running.
Important
Power supply is interrupted directly after the battery, by means of a key.
• Disconnect the battery before working on the electric system.
Interrupting power supply:
Turn key A of the battery master switch to position B and remove it.
Switching on power supply:
Insert key A in the battery master switch.
Turn the key down to the notched position C.