After about 4 seconds the pump will display the password (fig. 2):
Default password is "0000". To carry on press "P" key.
4.1 How to save / cancel changes / activate working modes
Once entered data into a menu, it is possible either to save them automatically by pressing "P" key or to
cancel any changes by pressing "ESC" key.
To activate a working mode (Constant, Divide, Multiply, PPM, Perc, MLQ, Batch, Volt, mA) select the
desired mode and confirm any changes by pressing "P" key.
How to switch on/ off the pump
"ESC" key can be used either to cancel any changes or to switch on/off the pump. To switch on/off the
pump press and keep this key pressed from the main menu (fig. 1). The pump will display:
To bring the pump back to operation press again "ESC" key until normal operating mode is restored.
Simple / Extended Setup Mode
The pump displays a choice on the access mode when choosing to make the SETUP.
If you programme the pump for the first time, select "FULL" as shown in fig. A by pressing "P" to confirm.
In this way the programming menu will completed with all entries and it will be possible to select the desired
working mode.
Then, to modify only the parameters of the selected programming mode, select "SHORT" by pressing "P"
to confirm, as shown in fig. B.
----------------
Note: The menu entry "SHORT" is not available if you enter the programming mode for the first
time or after a reset of the pump.
4.2 Priming procedure
PRIMING
To prime the pump without coming in contact with the chemical, follow the instructions below:
--
- properly connect all hoses (delivery, suction and drain hose)
- open the air valve by rotating the knob completely
Plug in the pump. After a short introduction of the pump model, as shown in fig. 4,
48
Fig. 2
Fig. 3
STROKES
100 SPM
password
FULL
0000
MENU
Fig. A
OFF
SHORT
MENU
VMS MF
R: 1.xx
WAITING
Fig. 4
00:59
STROKES
100 SPM
STROKES
100 SPM
password
0000
STROKES
100 SPM
OFF
----------------
password
0000
VMS MF
R: 1.xx
OFF
WAITING
----------------
00:59
VMS MF
STROKES
R: 1.xx
100 SPM
WAITING
STROKES
PRIMING
00:59
100 SPM
30 Sec.
STROKES
password
100 SPM
0000
PRIMING
OFF
30 Sec.
----------------
VMS MF
R: 1.xx
WAITING
00:59
FULL
MENU
SHORT
MENU
Fig. B
FULL
MENU
SHORT
MENU
FULL
MENU
SHORT
MENU
FULL
MENU
SHORT
MENU

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Dosamatic ppi

Table of Contents