KP100G

9. Technical Data

DC Side:
Max. input open-circuit voltage:
DC input voltage range
MPPT voltage range
Nominal input voltage
Max. input current
Max input current per one pair of DC connector
Max. input power
All pole disconnection on DC side:
Personnel protection:
AC Side:
Output values (grid)
Nominal power:
Peak power:
Nominal Output Current
THD of output current
Output voltage range:
Output frequency range:
All pole disconnection, grid side:
Over voltage Category
Self-consumption during nighttime
External interfaces
Data transmission:
Certifications
EMC
Grid monitoring:
Low voltage regulation:
Spanish regulation
Italian regulation
Enclosure
Protection (acc. to DIN EN 60529)
Weight and Dimensions
Dimensions (w x h x d):
Weight:
Ambient Conditions for Operation
Tolerable ambient temperature:
Tolerable relative humidity:
Efficiency
Max efficiency:
Euro efficiency:
Ppv(W) = 13 x Vpv
Example: V
is 400VDC, the maximum power could
PV
take by inverter in one string is 5200W.
V
800 VDC
PVO
200 to 800 V
V
300 to 800 V
PV1
640VDC
I
39ADC
max
13ADC
5,500W / Tracker
DC connectors (3 pairs)
Earth fault monitoring
P
10,000 W
Acnom
P
11,000 W
acmax
I
14.5A
AC_nom
3% or less
400Vac -15%+10% (KP100G-OD-ES)
400Vac -20%+15% (KP100G-OD-DE, KP100G-OD-IT)
47.5 to 50.2Hz (KP100G-OD-DE)
49.7 to 50.3Hz (KP100G-OD-IT)
49 to 51Hz (KP100G-OD-ES)
Mains monitoring with two independent
allocated switching devices
III
3.5W or less
RS-232C/RS-485/ type A to mini-B USB (electrically-isolated)
EN 61000-6-2, EN 61000-6-3 ,EN 61000-3-2
VDE0126-1-1 (KP100G-OD-DE)
EN50178
RD1663/2000 (KP100G-OD-ES)
ENEL DK5940 (KP100G-OD-IT)
Housing: IP65
452 × 583 × 152 mm
Approx. 34 kg
-20 to +55°C
0 to 95%, non-condensing,
96.5%
95%
Fig, 9-1 Load Graph of KP100G