Omron KP100G Technical Manual page 42

Grid connect photovoltaic inverter
Hide thumbs Also See for KP100G:
Table of Contents

Advertisement

KP100G
System Fault and Inverter Fault
Shown in "Status" row on the text display and Error display
No utility
E1-0:No Utility
Grid failure
E1-1:Grid OV
(Over voltage)
Grid failure
E1-2:Grid UV
(Under voltage)
Grid failure
E1-3:Grid OF
(Over frequency)
Grid failure
E1-4:Grid UF
(Under frequency)
Grid failure
E1-6:Islanding active
(Islanding active)
Grid failure
Over voltage
E1-7: OV instantly
instantly
Input voltage too
E2-1:PV over voltage
high
GFCI active
E2-3:Ground I Fault
Isolation failure
E2-4:Isolation fault
E5-9:AUTO TEST
AutoTest failed
FAILED
Temperature too
E3-4:Over temperature
high
Memory card full
A2-7:Memory Full
System Information
Serial Number
S/N:xxxxxxxxxxxxxxxx SN:xxxxxxxxxxxxxxxx
Firmware version
Version:xx.xx-xx.xx
SD card memory
MEMORY:xx.x%
DATE:DD/MM/YY XXX
XXX:SUN
MON
TUE
Date display
WED
THU
FRI
SAT
TIME:HH/MM/SS
Time display
GMT+xx
E1-0:Kein Netz
E1-0:SIN RED
E1-1:Netzfehler OV
E1-1:ERR Red OV
E1-2: Netzfehler UV
E1-2: ERR Red UV
E1-3: Netzfehler OF
E1-3: ERR Red OF
E1-4: Netzfehler UF
E1-4: ERR Red UF
E1-6:Inselbetriebs
E1-6:Modo isla detect
E1-7:OV sofort
E1-7:OV inmediata
E2-1:SOBRETENSION
E2-1:DC-Überspg
DC
E2-3:Fehlerstrom
E2-3:ERR DERIVACION E2-3:Err Dispersione
E2-4:ERR
E2-4:Isolationsfehle
AISLAMIENTO
E5-9:AUTO TEST fehler E5-9:ERR AUTO TEST
E3-4:
E3-4:Übertemperatur
SOBRETEMPERATURA
A2-7:Memory Full
A2-7:MEMORIA LLENA A2-7:Memoria piena
S/N:xxxxxxxxxxxxxxxx
Version:xx.xx-xx.xx
Versión:xx.xx-xx.xx
Speicher:xx.x%
MEMORIA:xx.x%
Datum:DD/MM/YY XXX
FECHA:DD/MM/YY XXX
XXX:Son.
XXX:DOM
Mon.
Die.
Mit.
Don.
Frei.
Sam.
Zeit:HH/MM/SS
HORA:HH/MM/SS
GMT+xx
GMT+xx
42
E1-0:Assenza rete
E1-1:Err Rete OV
E1-2:Err Rete UV
E1-3:Err Rete OF
E1-4:Err Rete UF
E1-6:Isola attiva
E1-7:OV immediata
E2-1:Sovratensione cc
E2-4:Err Isolameto
E5-9:Err Autotest
E3-4:Sovratemperatura
MAT:xxxxxxxxxxxxxxx
x
Versione:xx.xx-xx.xx
MEMORIA:xx.x%
DATA:DD/MM/YY XXX
XXX:DOM
LUN
LUN
MAR
MAR
MIE
MER
JUE
GIO
VIE
VEN
SAB
SAB
ORA:HH/MM/SS
GMT+xx
Utility is not available
Grid measured data is beyond
the specification (Over voltage)
Grid measured data is beyond
the specification (Under
voltage)
Grid measured data is beyond
the specification (Over
frequency)
Grid measured data is beyond
the specification (Under
frequency)
Utility is not available
(Islanding operation detected)
Grid measured data is beyond
the specification (Over voltage
instantly)
Input voltage higher than the
permissible 800V
Leakage current on ground
conductor is too high
Earth fault of the PV-panels or
failure of surge voltage
protection
Auto test failed
The internal temperature is
higher than normal value
There is not enough space to
store data
10 characters unique serial
number
The Master and Slave CPU
F/W version information
Memory utilization on SD card
Date display
DD: day
MM: Month
YY: Year
Time display

Advertisement

Table of Contents
loading

Table of Contents