KP100G
Connect to RS-485 interface of
another inverter
3. Slide the card into the slot as shown in Fig, 5-28.
4. Fix the card with 2 screws as shown in Fig, 5-29.
5. Fix the protection cover with 4 screws as shown in Fig, 5-30.
Terminal of RS-485 card
R- R+ T- T+
N.C. N.C.
N.C. means "No Connection
Fig, 5-27 Instruction of for wiring of terminal of RS-485 card
Fig, 5-28 Sliding the card into the slot
Fig, 5-29 Lock on the screws
Fig, 5-30 Fix the protection cover
R- R+ T- T+
N.C. N.C.
Connect to RS-485 interface of
another inverter
Fixed plate