Nreset Pin; Nautorun Pin; Miscellaneous (Hidden Jtag) - Laird BL600-SA Hardware Integration Manual

Single mode bluetooth low energy (ble) module
Hide thumbs Also See for BL600-SA:
Table of Contents

Advertisement

BL600-Sx Hardware Integration Guide
Single Mode BLE Module

5.9 nRESET pin

Table 18: nRESET pin
Signal Name
nRESET
Note:
For BL600-Sx-02 or BL600-Sx-03: To ensure nReset functions properly, you MUST place a 12K
resistor to GND on BL600 pin 23 (NC/SWDCLK) on your host board.
For BL600-Sx-04 or higher: Do not fit a resistor to GND on BL600 pin 23 (NC/SWDCLK).

5.10 nAutoRUN pin

nAutoRUN pin and Operating Modes
Refer to section
Self-contained Run mode
Interactive / Development mode

5.11 Miscellaneous (Hidden JTAG)

The BL600 SW consists of:
smart
BL600
BASIC runtime engine FW (loaded at production, may be upgraded customer).
BL600
smart
BASIC application script developed by customer (loaded through UART by customer).
To allow customer the capability to upgrade the BL600
released from Laird), the current
smart
upgrading
BASIC runtime engine FW over UART. Upgrade
2-wire (JTAG) interface has been supported since v1.1.50.0).
Signal Name (hidden name)
nRESET (SWDIO)
NC
(SWDCLK)
Laird can supply JTAG J-link programmer for this.
Only requirement is that the customer should use the following JTAG connector on the host PCB.
The JTAG connector MPN is as follows:
Reference
Part
JP1 Note1
FTSH-105
Note 1: Reference on BL600 development board schematic. Figure 9 shows the BL600-Sx-02 and
BL600-Sx-03 development schematic wiring only for the JTAG connector and BL600 module hidden
JTAG pins.
Americas: +1-800-492-2320 Option 2
Europe: +44-1628-858-940
Hong Kong: +852-2923-0610
www.lairdtech.com/bluetooth
Pin No
I/O
Comments
22
I
BL600 HW reset (active low). Pull the nRESET pin low for
minimum 100mS in order for the BL600 to reset.
smart
BASIC runtime engine firmware (v1.5.66.0 and since v1.2.54.0) allows
Pin No
I/O
Comments
22
I/O
23
I
Connect 12 K resistor to GND (BL600-Sx-02 and
BL600-Sx-03 only).
Description
Header, 1.27mm, SMD, 10-way, FTSH-105-01-L-DV Samtech
regarding operating modes and the nAutoRUN pin.
smart
BASIC runtime engine FW, to the latest version
smart
BASIC runtime engine FW via the hidden
29
CONN-HIG-BL600

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bl600-scBl600-st

Table of Contents