Recommended Operating Conditions; Pin Definitions - Laird CF10G Hardware Integration Manual

Table of Contents

Advertisement

SDC-CF10G
Hardware Integration Guide

Recommended Operating Conditions

Parameter
Supply Voltage
VDDIO, VDDBUS
VDDCORE, PLLVDD, AVDD
Logic Inputs
V
, Input High Voltage
INH
V
, Input Low Voltage
INL
Logic Outputs
V
, Output High Voltage
OH
V
, Output Low Voltage
OL
P
D
IN
EFINITIONS
Pin
Pin
Number
Name
1
GND
2
Slot0_data3
3
Slot0_data4
4
Slot0_data5
5
Slot0_data6
6
Slot0_data7
7
Slot0_nCE1
8
Slot0_addr10
9
Slot0_nOE
10
Slot0_addr9
11
Slot0_addr8
12
Slot0_addr7
13
VCC3_3
14
Slot0_addr6
15
Slot0_addr5
16
Slot0_addr4
17
Slot0_addr3
18
Slot0_addr2
19
Slot0_addr1
20
Slot0_addr0
21
Slot0_data0
22
Slot0_data1
23
Rfu_data2
24
Slot0_nIOIS16
25
Slot0_nCD2
Embedded Wireless Solutions Support Center:
http://ews-support.lairdtech.com
www.lairdtech.com/wireless
Min.
Typical
Max.
3.0
3.3
3.6
1.71
1.8
1.89
2.0
0.8
2.4
0.4
Power
I/O
Description
Type
Ground
Data bus, bit 3
Data bus, bit 4
Data bus, bit 5
Data bus, bit 6
Data bus, bit 7
Enable for even-numbered address bytes.
Active low.
Address bus, bit 10
I
Memory access output enable. Active low.
Address bus, bit 9
Address bus, bit 8
Address bus, bit 7
3.3V Module Power
Address bus, bit 6
Address bus, bit 5
Address bus, bit 4
Address bus, bit 3
Address bus, bit 2
Address bus, bit 1
Address bus, bit 0
Data bus, bit 0
Data bus, bit 1
Data bus, bit 2
Current access is 16 bit. Active low.
Card detect. Tied to ground in module.
10
Units
Comments
V
V
V
V
V
Current is determined
by the specific pad.
V
Americas: +1-800-492-2320