b. If you do plan to use the cable retention bracket, you will attach it to the chassis after the
12. Return the bottom access panel to the switch and reinsert the screws.

Mounting the Switch

Perform one of the following to install the switch:
If you are installing the I-Series switch as a freestanding device, install the rubber feet as
described in
Install the rack-mount kit (optional) and mount the switch to a 48.26-centimeter (19-inch) rack
or other secure location, as described in
Install the optional DIN clips and mount the switch to a DIN rail, as described in
the Switch to a DIN

Placing the Switch on a Flat Surface

When installing the switch on a flat surface, the installation of the rubber feet is recommended to
prevent the switch from sliding. Also, the surface must be able to support 4.36 kilograms
(9.6 pounds) of static weight.
To install the rubber feet, proceed as follows:
1.
Place the switch upside down on a sturdy flat surface.
2.
Remove the four rubber feet from the shipping box.
3.
Remove the protective strip from the back of one rubber foot and position it on one of the
corners on the bottom of the switch. Press firmly into place. Repeat this procedure to install
the remaining rubber feet in the other corners.
4.
After installing the rubber feet, return the switch to its upright position.
5.
Place the switch in its final location.

Installing the Switch into a Rack

The I-Series switch can be mounted in a standard EIA-310-D compliant 48.26-centimeter (19-inch)
equipment rack. To mount the switch into a rack, you must first install the optional rack-mount
kit, which consists of two brackets. Then you can attach the switch brackets to the rails using the
mounting screws provided.
Installing the rubber feet is optional if you are installing the switch in a rack. If you wish to install
the rubber feet, follow the procedure in
If you wish to mount the optional I3H-PWR external AC to DC power supply on a rack with the
I-Series switch, refer to
page 2-13.
port cables have been inserted, which at the same time will secure the IOM to the front of
the switch. Refer to
"Securing the IOM
"Placing the Switch on a Flat
Rail" on page 2-14.
"Attaching the External Power Supply to the Rack Mount
Note: The I-Series switch must not exceed the 2U high Richmond standard and must comply with
the requirements for mounting in a 19-inch (48.26-centimeter) rack.
Cables" on page 2-34 for more information.
Surface" on page 2-11.
"Installing the Switch into a
"Placing the Switch on a Flat
Enterasys I-Series Hardware Installation Guide 2-11

Mounting the Switch

Rack" on page 2-11.
"Installing
Surface" on page 2-11.
Bracket" on