HOST SETTI NGS
HOST TI MEOUT
10
CONTROL
CODES
STANDARD
CODES
ALTERNATE
CODES
ALTERNATE
CODES 2
CUSTOM
CODES
FEEDBACK
CHARACTERS
ENABLED
DI SABLED
ESC
SEQUENCES
ENABLED
DI SABLED
HEAT
COMMAND
ENABLED
DI SABLED
SPEED
COMMANDS
ENABLED
DI SABLED
TOF SENSI NG
COMMANDS
ENABLED
DI SABLED
SYMBOL SET
COMMAND
ENABLED
DI SABLED
CNTRL- CODES
( DATA)
ENABLED
DI SABLED
Ch a pt e r 4 – M e n u Syst e m
Cont rols t he com m unicat ions wit h a host device, where:
The " ignore host " set t ings for ESC SEQUENCES, HEAT, SPEED,
TOF SENSI NG, SYMBOL SET, CNTRL- CODES, STX- V SW
SETTI NGS, and MAX LENGTH will be unaffect ed when PL- Z Mode
is select ed ( see I nput Mode for det ails) .
Set s t he num ber of seconds ( 1 - 60) t hat an est ablished com m unicat ions port m ust
be idle before dat a can be received t hrough an alt ernat e port , where:
I f t he t im e- out period is exceeded before all dat a is received, t he
dat a will be ignored.
I s t he Default Set t ing.
Allows changes t o t he prefix of t he soft ware com m ands int erpret ed by t he print er,
where:
Use t hese charact ers: Hex 01 = SOH com m and; Hex 02 = STX com m and; count - by
= ^ ; Hex 1B = ESC; Hex 0x0D = Carriage Ret urn. ( Default Set t ing)
Use t hese charact ers: Hex 5E = SOH com m and; Hex 7E = STX com m and; count - by
= @; Hex 1B = ESC; Hex 0x0D = Carriage Ret urn.
Use t hese charact ers: Hex 5E = SOH com m and; Hex 7E = STX com m and; count - by
= @; Hex 1B = ESC; Hex 0x7C = Carriage Ret urn.
Each DPL com m and ( SOH, STX, CR, and count - by) m ay be select ed by ent ering t he
desired Hex code.
Allows t he print er t o ret urn a Hex 1E ( RS) aft er each label successfully print s, and a
Hex 1F ( US) aft er each label bat ch successfully print s, where:
Sends feedback charact ers t o t he host .
Does not send feedback charact ers t o t he host . ( Default Set t ing)
Allows dat a cont aining invalid ESC cont rol code sequences t o be processed, where:
Processes com m ands norm ally. ( Default Set t ing)
I gnores ESC sequences are during processing ( since som e syst em s send a " banner"
t o t he print er) . Bit m apped font downloads are disabled in t his m ode.
Det erm ines t he way t he DPL Heat com m and is handled, where:
Processes com m ands norm ally. ( Default Set t ing)
I gnores DPL Heat com m ands; inst ead, t he heat value is cont rolled via t he m enu
set t ing.
Det erm ines t he way DPL Print , Feed, Slew, and Reverse com m ands are handled,
where:
Processes com m ands norm ally. ( Default Set t ing)
I gnores DPL speed com m ands; inst ead, t he speeds are cont rolled via t he m enu
set t ing.
Det erm ines t he way in which DPL Gap, Cont inuous, and Reflect ive com m ands are
handled, where:
Processes com m ands norm ally. ( Default Set t ing)
I gnores DPL TOF com m ands; inst ead, TOF is cont rolled via t he m enu set t ing.
Det erm ines t he way in which DPL Single and Double Sym bol Set com m ands are
handled, where:
Processes com m ands norm ally. ( Default Set t ing)
I gnores DPL Sym bol Set com m ands; instead, t he Sym bol Set select ion is cont rolled
via t he m enu set t ing.
Det erm ines t he way in which DPL SOH, STX, CR, ESC, and ^ codes are handled,
where:
Processes com m ands norm ally. ( Default Set t ing)
I gnores DPL Cont rol Codes; inst ead, t he cont rol code funct ions are est ablished via
t he m enu set t ing.
4 3