Introduction

3.1
Intended use
The system must be used only for the pumping of normal household faecal wastewater, but not for combustible or explosive
liquids or solvents.
WARNING
Use of the system in a potentially explosive environment (ATEX) is not permitted.
All modifications or attachments that are carried out without the express and written permission of the manufacturer, the use
of non-genuine spare parts and repairs carried out by companies or persons not approved by the manufacturer will lead to a
loss of warranty.
The control unit is equipped with a protective circuit to protect the system's electrical components from damage in case of
possible voltage peaks.
This does not protect against lightning.
If such requirements exist, an appropriate protective device must be installed on site.
3.2
Scope of delivery
(A)
Tank (polymer) with waste-
water pump and level sensor
(B)
Tank (grey iron) with waste-
water pump and level sensor
(1)
Installation and operating instructions
(2)
(3)
Fixing material
(-)
Pipe penetration seal DN100/150 (not illustrated)
3.3
Product description
The Aqualift F XL lifting station (referred to as the "system" in the following) is designed for pumping off faecal and fae-
cal-free wastewater. The tank houses the pump(s) and the level sensor(s). The assemblies are matched to the KESSEL
control unit supplied.
The level sensor switching signals for the wastewater level are processed electronically in the control unit. When the switch-
on level has been reached, the pump-off function is activated. Pumping is ended when the level has fallen again by an
appropriate amount.
The system is available in three different versions (capacities) and with different pumps. Fittings and shut-off valves made of
polymer or grey iron are installed depending on the requirements.
Versions
Type designation
Aqualift F XL 200
Aqualift F XL 300
Aqualift F XL 450
010-907
Control unit
Tank volume
Mono
200 litres
300 litres
450 litres
Lifting station/Installation and operating instructions
Pump/control unit connection values
Duo
X
X
X
X
230V
400V
X
X
X
X
X
X
23 / 108