DIAGRAM FOR THE REGULATION OF THE ELECTRODE DISK DISTANCE
2
3
1 - Diffuser
2 - Internal diffuser
3 - Flame disk
4 - Ignition electrode
5 - Nozzles
6 - Nozzle holder
RECOMMENDED NOZZLES = MONARCH 30° HV° type
1
After installing the nozzles, make sure that the electrodes and disk
are correctly positioned according to the values indicated in mm.
It's advisable to check values after every intervention on head.
TBML 50 MC
/ ME
29 / 44
0006160028_201510
5
4
A
B
C
1 ÷ 2
17
3 ÷ 4
3 ÷ 4
ENGLISH
D
E
4 ÷ 5