TECHNICAL SPECIFICATIONS
MODEL
NATURAL GAS MAX. THERMAL POWER
NATURAL GAS MIN. THERMAL POWER
¹)NATURAL GAS EMISSIONS
NATURAL GAS OPERATION
NATURAL GAS MAX. HEATING CAPACITY
NATURAL GAS MIN. HEATING CAPACITY
NATURAL GAS MIN. PRESSURE
NATURAL GAS MAX PRESSURE
PROPANE GAS MAX. THERMAL POWER
PROPANE GAS MIN. THERMAL POWER
PROPANE GAS MAX. HEAT CAPACITY
PROPANE GAS MIN. HEAT CAPACITY
PROPANE GAS MIN PRESSURE
PROPANE GAS MAX PRESSURE
) PROPANE EMISSIONS
2
DIESEL OIL MAX. HEATING CAPACITY
DIESEL OIL MIN. HEATING CAPACITY
DIESEL OIL MAX THERMAL POWER
DIESEL OIL MIN. THERMAL POWER
³) DIESEL EMISSIONS
DIESEL VISCOSITY
DIESEL OPERATION
50 Hz FAN MOTOR
50Hz FAN MOTOR RPM
60Hz FAN MOTOR
60Hz FAN MOTOR RPM
50 Hz IGNITION TRANSFORMER
60 Hz IGNITION TRANSFORMER
VOLTAGE 50Hz
VOLTAGE 60Hz
50Hz* ELECTRICAL POWER
60Hz* ELECTRICAL POWER
DEGREE OF PROTECTION
EQUIPMENT
FLAME DETECTOR
SOUND PRESSURE**
WEIGHT WITH PACKING
WEIGHT WITHOUT PACKING
CO emissions, natural gas/propane ≤ 100 mg/kWh
* Total absorption at start with ignition transformer on.
The measurement has been carried out in Baltur's laboratory, in accordance with EN 150361 standard.
** Acoustic pressure measured one meter behind the equipment, with burner operating at maximum rated heat input, it refers to
Baltur's laboratory environment conditions and cannot be compared to measurements carried out in different locations.
***
Acoustic pressure was obtained characterizing Baltur's laboratory with a sample source, this measurement has an accuracy
of class 2 (engineering class) with a standard deviation f 1.5 dB(A).
Calorific power lower than reference conditions 15° C, 1013 mbar:
Diesel oil: Hi = 11.86 kWh/kg = 42.70 Mj/kg
Natural gas: Hi = 9.45 kWh/Stm³ = 34.02 Mj/Stm³
Lower calorific power:
Propane gas: Hi = 24.44 kWh/Stm³ = 88.00 Mj/Stm³
For different types of gas and pressure values, please contact our sales department.
mg/kWh
mg/kWh
mg/kWh
6 / 44
0006160028_201510
TBML 50 ME
kW
100
kW
500
Class III
Two-stage modulating
Stm³/h
52.9
Stm³/h
10.6
mbar
22.5
mbar
360
kW
500
kW
120
Stm³/h
20.45
Stm³/h
4.9
mbar
19.5
mbar
360
Class III
kg/h
42.15
kg/h
16.9
kW
500
kW
200
Class II
5.5 cst/20°C - 1.5° E / 20°C
Two-stage
kW
0.65
r.p.m.
2830
kW
0.65
r.p.m.
3430
26 kV - 48 mA - 230 V
26 kV - 48 mA - 230 V
3N ~ 400 V ± 10%
3N ~ 380 V ± 10%
kW
1.1
kW
1.1
IP 40
LME 73
UV photocell
dBA
75
kg
57
kg
50.5