Manually checking the cleaning device functions
Safety
Danger due to improper commissioning.
This can result in damage to property.
▶
Manually check-
NOTE!
ing the cleaning
device functions
When the slot for the "Start cleaning" and "Spray in parting agent" screws is posi-
tioned horizontally, the respective function is deactivated.
1
2
3
Start cleaning function
The following must be checked when the function is being performed:
-
-
-
4
Start cleaning
Spray in parting agent function
The following must be checked once the function has been performed:
-
44
CAUTION!
Before starting the automatic cleaning process, check the functions of the cleaning
device manually - see description below.
Move the welding torch to the cleaning position
Disconnect the cleaning device from the robot control
Establish a compressed air supply to the cleaning device
Function of the gas nozzle clamping device (clamping device piston extends)
The insertion depth of the cleaning cutter in the gas nozzle (lifting device moves the
cleaning motor upwards)
Function of the cleaning motor (cleaning motor starts)
whether the gas nozzle is coated with a sufficient layer of parting agent
5
Deactivating the function