2.2.2. Direct connection of master and slave
A single slave charging station can be connected directly to the master charging station via LAN.
Fig. 2-3: Direct connection of master and slave
1 EVLunic Pro M (master)
In this case, the master charging station must be configured as a DHCP server. The IP address is then
assigned to the slave charging station by the master charging station.
2.2.3. Connection via router or switch
If there are multiple slave charging stations, these must be connected to the master charging station via
a router or switch. The connection of the charging station to the router/switch is made via LAN
Fig. 2-4: Connection via router or switch
1 Router/Switch
3 EVLunic Pro S (slave)
STATUS
Released
© Copyright 2019 ABB. All rights reserved.
2 EVLunic Pro S (slave)
2 EVLunic Pro M (master)