If no OCPP backend is used, the "FirstLocal" authorization mode must be set for authorization to be
active.
*) The first 1000 RFID cards are relayed from the OCPP backend to the master charging station where
they are stored locally. If the connection to the higher-level OCPP backend fails, the master charging
station authorizes these stored RFID cards throughout the network until the connection is
reestablished.
4.2.2. Displays and signals
During RFID authorization, the charging station can display different light patterns on the LED bar and
emit acoustic signals.
LED bar
Display
Flashing green (every 3 seconds)
Flashing blue (every 3 seconds)
Illuminated orange (once)
Acoustic signals
Signal
Single tone
Rising tone sequence
Falling tone sequence
The charging station can also display a text concerning the RFID authorization, e.g. "accepted card". This
text can be customized via the web interface.
4.2.3. RFID authorization without OCPP backend connection
The following options are available for managing RFID cards:
At the RFID reader of the charging station
In the web interface
Managing RFID cards at the RFID reader
Both the master RFID card and all slave RFID cards can be taught in directly at the RFID reader of the
charging station. To teach in an RFID card, no charging session may be active and no vehicle may be
plugged into the charging station.
STATUS
Released
© Copyright 2019 ABB. All rights reserved.
Description
Authorization is done correctly.
The charging station is waiting for authorization
to enable a charging process. Authorization
necessary, either with RFID card or by an external
input.
The RFID card is invalid.
Description
RFID card has been read.
RFID card has been accepted.
RFID card has been rejected (no authorization).