3.5.1. Create configuration
If this has not yet been done, a first EVLunic Pro M must be configured with the desired settings. These
settings serve as the basis for the configuration of additional EVLunic Pro M.
The easiest way to configure the charging station is via the web interface.
On the graphical user interface the available settings and selection fields are provided with short
explanations.
Information
Not all settings available in the web interface can be transferred via USB stick to additional charging
stations.
3.5.2. Read out configuration
In order to be able to transfer the configuration of one EVLunic Pro M to additional EVLunic Pro M, the
USB stick must be connected to the USB interface (in the connection panel) of the operationally ready
and already configured charging station. The charging station automatically transfers the configuration
to the USB stick and displays the process on the display. When finished, the charging station indicates
that the USB stick can be removed by displaying "remove usb".
Information
Do not remove the USB stick during the writing process! Otherwise it cannot be used for another
configuration.
3.5.3. Adapt configuration file
To adapt the configuration file, the USB stick must be connected to a computer. The configuration file
was saved on the USB stick in the directory CFG as *.conf file. In order to use the file to configure other
charging stations, the file name and parts of the content must be adapted.
Adapt file name
The file name contains the serial number of the charging station from which the configuration was read
out. This serial number must be deleted from the file name.
A configuration file without a serial number in the file name can be used to configure multiple charging
stations. If the configuration is to be valid for only exactly one charging station, the file name must
contain the serial number of the desired charging station.
Adapt content
The specific configurations that only apply to one charging station must be adapted or deleted in the
configuration file.
All settings are listed in the configuration file. The figure below shows a section of a configuration file.
To the left of the equal sign "=" is the name of the setting. To the right of the equal sign is the set value.
STATUS
Released
© Copyright 2019 ABB. All rights reserved.
DOCUMENT ID.
TBA
CHARG ING STATIO N
REV.
LANG.
PAGE
A
EN
24/37

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents