6) CL33800 Hard Wiring Instructions
6.5) M35 Power/Remote Unlocking Harness
-9 VDC
784
9VDC
+9 VDC
Power Supply
EGND
120 VAC L/N/G
Normally Open
momentary switch
(Remote unlock
- REX option)
NO
C
Black, 1
Red, 2
White, 3
Green, 4
Orange, 5
Blue, 6
Brown, 7
Yellow, 8
with 8-pin connectors,
8 wires and pigtail harness
Door
Outside
Escutcheon
Fig. 3
Power/Remote Unlocking
ElectroLynx Wiring System
QC8 Electric Hinge
6 AA batteries MUST be removed from
controller if 784 Power supply is used.
Inside
Escutcheon
M35
Power/Remote
Unlocking
Harness
ElectroLynx Door Harness
with 8 & 4-pin connectors.
Harness location is
dependent on door type.
16
ASSA ABLOY
Remote Power and
Ground Tab
REX Connector TB2
Motor
Connector
TB1
1 2 3 4 5 6 7 8
REX Input
Connect to
Device.
Only used in
combination
with the M861
Option.
It may be left
unconnected.