Download Print this page

Assa Abloy Corbin Russwin Access 800 Series Installation Instructions Manual page 10

Hide thumbs Also See for Corbin Russwin Access 800 Series:

Advertisement

CL33800 WI1/IP1 Series Cylindrical Lock
Installation (or Replacement) of Batteries, Battery Keeper and Cover
11
1. To install the batteries, first remove the battery cover using the T20 bit provided (Fig. 11C).
2. Unscrew the bottom screw of the battery keeper and remove the battery keeper, being
careful not to break the tabs at top holding it in place. (Fig 11A)
3. Place (6) "AA" batteries in the compartment, being careful to align polarity properly (Fig.
11B)
4. Replace battery keeper being careful to engage tabs at top to hold it in place. (Fig 11A)
5. Attach battery cover to inside escutcheon making sure to line up tabs with retaining slots in
battery cover.
6. Secure with the security screw and T20 bit. (Fig 11C)
Fig. 11A
4) Installation Instructions
Fig. 11B
Tabs
Fig. 11C
10
ASSA ABLOY
C A U T I O N
DOOR MUST REMAIN OPEN
DURING INSTALLATION.
USE DOOR STOP.
TEST
FOR PROPER
OPERATION
BEFORE
CLOSING
DOOR
Retaining
Slots
Security Screw
T20 Bit