6) CL33800 Hard Wiring Instructions
Installation:
®
1. ElectroLynx System Wiring Instructions (refer to Fig. 1 and Fig. 4)
a. Look for the mating part on ASSA ABLOY doors and frames. Then plug in all
connectors as shown in Fig. 4 during product installation.
b. Hard wire forced/propped, hard power and/or remote unlock (REX) as shown.
®
2. Non-ElectroLynx System Wiring Instructions (refer to Fig. 1 and Fig. 4)
a. Cut the 8-pin connector off the Power/Remote Unlock harness and hard wire
to non-ElectroLynx door harness. Remote power requires three conductors
and remote unlock requires two conductors.
b. Hard wire door harness to power transfer device.
c. Hard wire forced/propped, hard power and/or remote unlock (REX), as shown.
®
19
ASSA ABLOY
ElectroLynx® is a registered trademark of ASSA ABLOY Inc.
Copyright © 2014 Corbin Russwin, Inc. All rights reserved.
Reproduction in whole or in part without the express written
permission of Corbin Russwin, Inc. is prohibited.
®