    TABLE OF CONTENTS Preparing for Installation ............4 Function ................. 4 Specifications ..............4 Mounting Information ........... 4 Safety Instructions ............4 Installation Requirements ............6 Installing ..................7 Calibrating ................... 8 Troubleshooting ................. 9...
  • Page 3: Preparing For Installation

    Preparing for Installation Function The SE feature is available on all 3000/8000 series exit devices and provides for latch retraction of the device from a remote location. The exit device is Fail Secure—in the event of a power failure, the exit device defaults to a latched condition. The linear actuator is rated for both continuous and intermittent operation.
  • Page 4 Figure 1. Adams Rite Model # PS-SE Power Supply Figure 2. Wire Sizing...
  • Page 5: Installation Requirements

    Installation Requirements The following are the installation requirements/comments for the SE feature exit device: NOTE 1: Recommended circuit hookup for the Adams Rite power supply is provided in Figure 1, “Adams Rite Model # PS-SE Power Supply,” and the owner’s manual supplied with the power supply.
  • Page 6: Installing

    CAUTION: This product must be installed in accordance with all applicable building and life safety codes. Installing NOTE: The exit device template should be reviewed to determine applicable bar height for installation. 1. INSTALL the exit device with SE feature in accordance with the specific exit device installation instruction.
  • Page 7: Calibrating

    NOTE 1: Proper calibration needs to occur on all SE exit devices when installed prior to initial power up. NOTE 2: Labels are affixed to all SE exit devices to detail calibration steps, and also provide a Quick Response (QR) code that is a link to a calibration instruction video. Calibrating NOTE: Verification of the PCBA type ensures that the correct one is installed when there is an issue that could be...
  • Page 8: Troubleshooting

    Troubleshooting No power to the exit device 1. ENSURE that the power connector is connected properly, all wiring from the power supply is continuous (without opens), and there are no shorts to ground. Neither exit device retracts after the control switch is activated 1.
  • Page 9 IN1 and IN2 lights do not light in response to input switches 1. CHECK to see if there is an open connection in the field wiring existing between the Adams Rite power supply and the control switch used for activating the latch solenoids. 2.