Table of contents Sirona Dental Systems GmbH Operating Instructions for the Acquisition Unit CEREC AC Connect Table of contents Dear Customer,....................... Contact information..................General data ......................Structure of the document................2.1.1 Identification of the danger levels ..........2.1.2 Formats and symbols used............
Page 3
Sirona Dental Systems GmbH Table of contents Operating Instructions for the Acquisition Unit CEREC AC Connect Installation and startup.................... Transport and unpacking ................Disposal of packaging materials ..............Scope of supply ................... Initial startup....................6.4.1 Controls and functional elements........... 6.4.2 Operating state LED ..............
Page 4
Table of contents Sirona Dental Systems GmbH Operating Instructions for the Acquisition Unit CEREC AC Connect 8.2.1.4 Refitting the prismatic tube ........... 8.2.1.5 Pre-cleaning of the prismatic tube ........ 8.2.1.6 Wipe disinfection for the camera and prismatic tube..8.2.1.7 High-level disinfection of the prismatic tube without sapphire glass ..............
Sirona Dental Systems GmbH 1 Dear Customer, Operating Instructions for the Acquisition Unit CEREC AC Connect Dear Customer, ® Thank you for purchasing your CEREC AC Connect from Sirona. This unit enables you to create digital exposures and to transmit these to your dental laboratory.
2 General data Sirona Dental Systems GmbH Operating Instructions for the Acquisition Unit CEREC AC Connect General data Please read this document completely and follow the instructions exactly. You should always keep it within reach. Original language of the present document: German.
Sirona Dental Systems GmbH 2 General data Operating Instructions for the Acquisition Unit CEREC AC Connect Battery warranty The battery is subject to wear and the warranty period of 6 months therefore deviates from the period specified for the entire device.
Page 8
2 General data Sirona Dental Systems GmbH Operating Instructions for the Acquisition Unit CEREC AC Connect Relative humidity during storage and transport Air pressure during storage and transport...
Sirona Dental Systems GmbH 3 General description Operating Instructions for the Acquisition Unit CEREC AC Connect General description Certification CE mark This product bears the CE mark in accordance with the provisions of Council Directive 93/42/EEC of June 14, 1993 concerning medical devices.
4 Safety Sirona Dental Systems GmbH Operating Instructions for the Acquisition Unit CEREC AC Connect Safety Basic safety information 4.1.1 Prerequisites NOTE Restrictions regarding installation site The system is not intended for operation in areas subject to explosion hazards. NOTE Do not damage the unit! The unit can be damaged if opened improperly.
Accessories In order to ensure product safety, this device may be operated only with original Sirona accessories or third-party accessories expressly approved by Sirona. The user is responsible for any damage resulting from the use of non-approved accessories. 4.1.7.1 Included accessories ●...
4 Safety Sirona Dental Systems GmbH Operating Instructions for the Acquisition Unit CEREC AC Connect Safety labels Fuses NOTE Use ONLY fuses of the same type! Plug connections of external interfaces...
Page 13
Sirona Dental Systems GmbH 4 Safety Operating Instructions for the Acquisition Unit CEREC AC Connect CAUTION Additional devices connected to external interfaces must be tested according to the relevant standards, e.g.: EN 60601-1:1990 + A1:1993 + A2:1995 based on IEC 60601-1, EN...
4 Safety Sirona Dental Systems GmbH Operating Instructions for the Acquisition Unit CEREC AC Connect Electrostatic charge 4.3.1 ESD warning labels ESD warning label CAUTION Risk of injury or damage to components from electrostatic discharge For electrical components labeled with an ESD warning label, observe the following instructions.
Sirona Dental Systems GmbH 4 Safety Operating Instructions for the Acquisition Unit CEREC AC Connect 4.3.3 About the physics of electrostatic charges What is an electrostatic charge? An electrostatic charge is a voltage field on and in an object (e.g. a human body) which is protected against conductance to ground potential by a nonconductive layer (e.g.
4 Safety Sirona Dental Systems GmbH Operating Instructions for the Acquisition Unit CEREC AC Connect Wireless phone interference with equipment The use of mobile wireless phones in practice or hospital environments must be prohibited to ensure safe operation of the unit.
Sirona Dental Systems GmbH 5 Technical information Operating Instructions for the Acquisition Unit CEREC AC Connect Technical information Technical description CAD system for high-precision intraoral optical impressions ● High-resolution, heated oral camera (3D camera) with removable prism tube (prism tube sterilizable with hot air) ●...
Page 18
5 Technical information Sirona Dental Systems GmbH Operating Instructions for the Acquisition Unit CEREC AC Connect ● Network card: Ethernet 10/100/1000 Mbit/s on- board ● WLAN card: Linksys WMP600N ● Sound card: Realtek HD Audio onboard ● Graphics card: N450GTS M2D1GD5 (PCIe 16x, 1GB)) ●...
Sirona Dental Systems GmbH 5 Technical information Operating Instructions for the Acquisition Unit CEREC AC Connect Technical data Type designation CEREC AC Acquisition unit Rated line voltage for Europe 230 VAC / 50Hz Rated current for Europe 1.5 A Rated line voltage for USA...
5 Technical information Sirona Dental Systems GmbH Operating Instructions for the Acquisition Unit CEREC AC Connect Dimensions and weight Dimensions (WxHxD) in mm 350 x 1210 x 470mm in inches 13¾ x 47⅝ x 18½“ Weight ● without monitor and battery pack 38 kg (83.8 lbs)
Sirona Dental Systems GmbH 5 Technical information Operating Instructions for the Acquisition Unit CEREC AC Connect 5.3.2 Interference immunity The UNIT is intended for operation in the electromagnetic environment specified below. The customer or user of the UNIT should make sure that it is used in such an environment.
Page 22
5 Technical information Sirona Dental Systems GmbH Operating Instructions for the Acquisition Unit CEREC AC Connect Interference immu- IEC 60601-1-2 Test level Compliance level Electromagnetic environment – nity tests guidelines Conducted RF in- d= [1.2] √P terference 150 kHz to 80 MHz...
Sirona Dental Systems GmbH 5 Technical information Operating Instructions for the Acquisition Unit CEREC AC Connect 5.3.3 Working clearances Recommended working clearances The UNIT is intended for operation in an electromagnetic environment, between portable and mobile RF where radiated RF interference is checked. The customer or the user of...
Operating Instructions for the Acquisition Unit CEREC AC Connect Installation and startup Transport and unpacking All products from Sirona are carefully checked prior to shipment. Please perform an incoming inspection immediately after delivery. 1. Check the delivery note to ensure that the consignment is complete.
Sirona Dental Systems GmbH 6 Installation and startup Operating Instructions for the Acquisition Unit CEREC AC Connect Initial startup 6.4.1 Controls and functional elements Overview of the front panel Monitor ON/OFF switch Center trackball button Membrane keyboard Left trackball button...
Page 26
6 Installation and startup Sirona Dental Systems GmbH Operating Instructions for the Acquisition Unit CEREC AC Connect Operating state LED ON button Components of the Bluecam Press detent to release Protective cap Prismatic tube Front lens Prism Bluecam calibration set Camera support (6 pcs), Order No.: 59 45 360...
Page 27
Sirona Dental Systems GmbH 6 Installation and startup Operating Instructions for the Acquisition Unit CEREC AC Connect Overview of rear side Fuses Power connection Main switch USB port I = ON, 0 = OFF NOTE Waiting time after shutting down If you have shut down the device using the main switch, wait at least 10 seconds before restarting.
6 Installation and startup Sirona Dental Systems GmbH Operating Instructions for the Acquisition Unit CEREC AC Connect 6.4.2 Operating state LED Operating state LED ON button LED not lit: Acquisition unit is switched off at main switch. LED lights up yel-...
Sirona Dental Systems GmbH 6 Installation and startup Operating Instructions for the Acquisition Unit CEREC AC Connect ü The line voltage can be switched from 230V to 100V or 115V and vice versa. 1. To do this, unlatch the fuse module with a screwdriver and pull the module out.
6 Installation and startup Sirona Dental Systems GmbH Operating Instructions for the Acquisition Unit CEREC AC Connect 6.4.5 Insert battery (optional) Bottom door Battery cover Storage battery Battery connector 1. Open the lower door on the back panel. NOTE Open with coin.
Ä The unit is dry and can be put into operation. CAUTION Use only the supplied power cord Use only the power cord supplied by Sirona to connect the acquisition unit to the power supply. If the acquisition unit is switched on at the main switch, it can be activated with the ON button.
6 Installation and startup Sirona Dental Systems GmbH Operating Instructions for the Acquisition Unit CEREC AC Connect Monitor ON/OFF switch ON button 1. Switch the acquisition unit on at the main switch. 2. Switch the acquisition unit on at the ON switch.
At least every three months the CEREC AC Connect acquisition unit must be connected to the mains supply to charge the storage batteries.
Page 34
6 Installation and startup Sirona Dental Systems GmbH Operating Instructions for the Acquisition Unit CEREC AC Connect The color of the symbol has the following meaning: ● Green = line voltage present, fan functioning, temperature OK. ● Yellow = Unit running in battery-powered mode, all other operating parameters OK.
Page 35
Sirona Dental Systems GmbH 6 Installation and startup Operating Instructions for the Acquisition Unit CEREC AC Connect Monitoring window Explanation When the battery charge is almost depleted, the shut- down window opens. The operating system is then shut down after 30s and the PC can then be switched off.
7 Operation Sirona Dental Systems GmbH Operating Instructions for the Acquisition Unit CEREC AC Connect Operation General Aligning the Bluecam The direction of acquisition must If the Bluecam is held at an coincide with the insertion axis of oblique angle to the prepared in-...
Sirona Dental Systems GmbH 7 Operation Operating Instructions for the Acquisition Unit CEREC AC Connect Angle of incidence/steepness If the angle of incidence of the Bluecam is too large, the mesial cervical step moves outside of the focal depth range of the Bluecam as shown in the illustration.
7 Operation Sirona Dental Systems GmbH Operating Instructions for the Acquisition Unit CEREC AC Connect 7.2.3 Direction of application right wrong It is essential that the material is applied perfectly, especially in the edge and marginal areas. It is therefore advisable to aim the cannula directly at all edge and marginal areas.
Sirona Dental Systems GmbH 7 Operation Operating Instructions for the Acquisition Unit CEREC AC Connect Preparing the exposure Pushing on the camera support ➢ Push the camera support onto the camera as illustrated. Pushing on the camera support Positioning the camera...
7 Operation Sirona Dental Systems GmbH Operating Instructions for the Acquisition Unit CEREC AC Connect Acquisition control With the CEREC camera you can switch between two acquisition modes: ● manual ● automatic After being switched on, the CEREC camera is set to automatic acquisition control.
Sirona Dental Systems GmbH 7 Operation Operating Instructions for the Acquisition Unit CEREC AC Connect 4. Then check the above points once again. Take care that the optical impression is sufficiently bright, sharp and free of motion blurring. If you do not observe these points, one of them may have a negative effect upon the subsequent procedure.
Some countries have legal regulations which require regular safety inspections of electrical devices or systems by the operator. Sirona would like to draw your attention to the fact that a so-called "retest" (repeat test) must be carried out for the CEREC AC acquisition unit every three years at the latest.
Sirona Dental Systems GmbH 8 Maintenance Operating Instructions for the Acquisition Unit CEREC AC Connect 8.1.2 Monitor screen Cleaning NOTE Never spray the monitor screen with disinfectant or cleaning agents! The monitor screen must be wiped with a soft cloth.
8 Maintenance Sirona Dental Systems GmbH Operating Instructions for the Acquisition Unit CEREC AC Connect CEREC Bluecam CAUTION If the Bluecam has accidentally fallen down, check to make sure that the front lens and prism are not damaged. If it has been damaged, the CEREC Bluecam must not be used on patients any more.
Sirona Dental Systems GmbH 8 Maintenance Operating Instructions for the Acquisition Unit CEREC AC Connect 8.2.1.2 Components of the CEREC Bluecam without sapphire glass Press detent to release Camera support 6 pcs, Order No. 5945360 Prismatic tube Protective cap Prism without sapphire...
8 Maintenance Sirona Dental Systems GmbH Operating Instructions for the Acquisition Unit CEREC AC Connect 8.2.1.4 Refitting the prismatic tube NOTE Do not use CEREC 2 / CEREC 3 prismatic tubes. NOTE Risk of damaging the front lens or prism.
CIDEX OPA disinfectant is available in your country via your dealer: A HLD set to support the HLD processes can be ordered from Sirona with REF 63 46 907. 1. Remove the camera support (if present). 2. Carry out a preliminary cleaning process (see "Pre-cleaning of the prismatic tube ...
Page 48
8 Maintenance Sirona Dental Systems GmbH Operating Instructions for the Acquisition Unit CEREC AC Connect 7. Carefully fill the HLD container up to the 40 ml mark ("Bluecam" mark). A funnel can be used to help pour in the liquid. Do not spill the disinfectant.
Sirona Dental Systems GmbH 8 Maintenance Operating Instructions for the Acquisition Unit CEREC AC Connect 8.2.1.8 Hot air sterilization of the prismatic tube NOTE Hot air sterilization and high-level disinfection must not be combined. The process for hot air sterilization is as follows: 1.
8 Maintenance Sirona Dental Systems GmbH Operating Instructions for the Acquisition Unit CEREC AC Connect 8.2.2.2 Components of the CEREC Bluecam with sapphire glass Press detent to release Camera support 6 pcs, Order No. 5945360 Prismatic tube Protective cap Prism with sapphire glass...
Sirona Dental Systems GmbH 8 Maintenance Operating Instructions for the Acquisition Unit CEREC AC Connect 8.2.2.3 Removing the prismatic tube Detent 1. Press the prismatic tube against the camera body. 2. Press detent A. NOTE Risk of damaging the front lens or prism.
8 Maintenance Sirona Dental Systems GmbH Operating Instructions for the Acquisition Unit CEREC AC Connect 8.2.2.6 Wipe disinfection for the camera and prismatic tube NOTE Do not spray the CEREC Bluecam with or immerse it in cleaning agents or disinfectants! 1.
CIDEX OPA disinfectant is available in your country via your dealer: A HLD set to support the HLD processes can be ordered from Sirona with REF 63 46 907. 1. Remove the camera support (if present). 2. Carry out a preliminary cleaning process (see "Pre-cleaning of the prismatic tube ...
8 Maintenance Sirona Dental Systems GmbH Operating Instructions for the Acquisition Unit CEREC AC Connect Calibrating the Bluecam IMPORTANT If you are using software version 3.8, calibrate the Bluecam with the installed CEREC SW or CEREC Connect SW software. The scanning technique used by the system requires the use of a calibrated Bluecam.
Page 55
Sirona Dental Systems GmbH 8 Maintenance Operating Instructions for the Acquisition Unit CEREC AC Connect Part A Calibration You will be prompted to fasten the calibration set with part A to the Bluecam. Part A 1. Slide the calibration set with part A as far as it will go toward the camera handle.
8 Maintenance Sirona Dental Systems GmbH Operating Instructions for the Acquisition Unit CEREC AC Connect Replacing the main fuse WARNING Electric shock Disconnect the power plug at the unit end before replacing the fuses. NOTE Fuse type Use only fuses of the same type in the fuse module!
Sirona Dental Systems GmbH 8 Maintenance Operating Instructions for the Acquisition Unit CEREC AC Connect Replacing fuse F3 WARNING Electric shock Disconnect the power plug at the unit end before replacing the fuses. NOTE Fuse type Use only fuses of the same type!
8 Maintenance Sirona Dental Systems GmbH Operating Instructions for the Acquisition Unit CEREC AC Connect Charge battery (optional) NOTE Reduced buffer cycles After around 1000 buffer cycles the capacity of the battery fades due to the nature of the battery technology used.
Sirona Dental Systems GmbH 8 Maintenance Operating Instructions for the Acquisition Unit CEREC AC Connect Replace battery (optional) Bottom door Battery cover Storage battery Battery connector 1. Open the lower door on the back panel. NOTE Open with coin. Use a coin to open the latch. Turn counterclockwise.
The storage battery pack is marked with the adjacent symbol. Disposal of the storage battery pack with domestic refuse is not compatible with the objectives of environmentally sound recycling/disposal. Send in the replaced storage battery pack to Sirona (see the reverse side of these operating instructions for the mailing address).
Sirona Dental Systems GmbH 10 Appendix Operating Instructions for the Acquisition Unit CEREC AC Connect Appendix DVD playback 10.1 DVD videos can be played back on the acquisition unit via "Windows Media Center" . ➢ Start the program via the corresponding icon or via "Start" / "All Programs"...
10 Appendix Sirona Dental Systems GmbH Operating Instructions for the Acquisition Unit CEREC AC Connect Seal on PC slide-in module 10.3 NOTE If the seal is broken, all warranty claims regarding the PC slide- module automatically expire. The PC slide-in module may be opened only by an authorized dental technician.
Page 63
Sirona Dental Systems GmbH 10 Appendix Operating Instructions for the Acquisition Unit CEREC AC Connect 3. Insert the diagnostics tools CD into the drive. 4. Use the arrow keys to select "CD/DVD:…" in the menu and hit the "Enter" key.
10 Appendix Sirona Dental Systems GmbH Operating Instructions for the Acquisition Unit CEREC AC Connect 10.4.2 Test procedure 10.4.2.1 Customer Diagnostics ü You have started the "Customer Diagnostics" test and the system configuration is displayed. 1. Using the information in the system configuration, check whether the system corresponds to the default settings.
Page 65
Sirona Dental Systems GmbH 10 Appendix Operating Instructions for the Acquisition Unit CEREC AC Connect Ä The result, i.e. "Pass" or "Fail", appears at the end of the test (see sections entitled "Test result: Pass" or "Test result: Fail"). 3. On completion of the test, press any key to go on to the test dialog.
10 Appendix Sirona Dental Systems GmbH Operating Instructions for the Acquisition Unit CEREC AC Connect 10.4.2.2 Technician Diagnostics ü You have started the "Technician Diagnostics" test and the system configuration is displayed. 1. Using the information in the system configuration, check whether the system corresponds to the default settings.
Page 67
Sirona Dental Systems GmbH 10 Appendix Operating Instructions for the Acquisition Unit CEREC AC Connect 3. On completion of the test, press any key to go on to the test dialog. Tip: You can scroll to the individual test steps using the arrow keys.
10 Appendix Sirona Dental Systems GmbH Operating Instructions for the Acquisition Unit CEREC AC Connect 10.4.2.3 Sirona Windows Diagnostics General The "Sirona Windows Diagnostics" test loads the PC-specific components simultaneously over a long period of time. This period of time is determined by the user.
Sirona Dental Systems GmbH 10 Appendix Operating Instructions for the Acquisition Unit CEREC AC Connect Test result: Pass No errors were found on the PC-specific hardware. Replacing the PC component or the PC is not advisable. Test result: Fail An error was found on the PC-specific hardware. Replacing the PC component or the PC may be required.
Index Sirona Dental Systems GmbH Operating Instructions for the Acquisition Unit CEREC AC Connect Index Numeric 3D calibration set, 26 Dimensions, 20 Disinfectants, 43 Disinfecting, 43 Acquisition Disposal of old electrical and electronic devices, 60 optical, 37 Acquisition unit Overview, 25 enretec GmbH, 60 Air pressure Operation, 19 Foot pedal, 25 Storage, 19...
Page 71
Sirona Dental Systems GmbH Index Operating Instructions for the Acquisition Unit CEREC AC Connect Network, 16 Temperatur Network installation, 29 Storage, 19 Transport, 19 Trackball, 25 ON button, 28, 31 Cleaning, 43 Online help, 32 trackball button Operating mode, 19 center, 25 Operating state LED, 28 left, 25, 31 right, 25, 31 Transport, 24 Packaging, 24...
Need help?
Do you have a question about the CEREC AC Connect and is the answer not in the manual?
Questions and answers