Emerson Rosemount 2051CF Quick Start Manual page 33

Hide thumbs Also See for Rosemount 2051CF:
Table of Contents

Advertisement

March 2020
Markings
Table 10-2: Input Parameters
Input parameter
Voltage U
Current I
Power P
i
Capacitance C
Inductance L
Special Conditions for Safe Use (X):
1. If the equipment is fitted with an optional 90 V transient suppressor,
it is incapable of withstanding the 500 V isolation from earth test and
this must be taken into account during installation.
2. The enclosure may be made of aluminum alloy and given a protective
polyurethane paint finish; however care should be taken to protect it
from impact and abrasion when located in Zone 0.
IA ATEX FISCO
Certificate
Standards
Markings
Table 10-3: Input Parameters
Input parameter
Voltage U
Current I
Power P
i
Capacitance C
Inductance L
Special Conditions for Safe Use (X):
1. If the equipment is fitted with an optional 90 V transient suppressor,
it is incapable of withstanding the 500 V isolation from earth test and
this must be taken into account during installation.
Quick Start Guide
II 1 G Ex ia IIC T4 Ga (–60 °C ≤ T
HART
30 V
i
200 mA
i
1 W
0.012 μF
i
0 mH
i
Baseefa08ATEX0129X
EN60079-0:2012+A11:2013, EN60079-11:2012
II 1 G Ex ia IIC T4 Ga (–60 °C ≤ T
FISCO
17.5 V
i
380 mA
i
5.32 W
0 μF
i
0 mH
i
Quick Start Guide
≤ +70 °C)
a
Fieldbus/PROFIBUS
30 V
300 mA
1.3 W
0 μF
0 mH
≤ +60 °C)
a
33

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rosemount 2051