This section covers the mechanical and electrical installation of the unit. For rack mount models, use 4
#10-32 mounting screws to secure the unit to a standard 19" rack. Please refer to figures 3.1, 3.2, and
3.3 for diagrams of the controller back panel and electrical connections.
The following electrical connections must be made:
Azimuth and Elevation Motor Drive - 4 wires (2 for each axis)
These cables connect the controller to the azimuth and elevation motors. The conductors must be
sized appropriately so that sufficient voltage is supplied to the motors. The voltage supplied to the
motors will be the output voltage from the controller less the voltage drop caused by the resistance of
the wires.
The output voltage of the controller is a function of the current supplied to the motors. The voltage drop
in the wires connecting the controller to the antenna is determined by the wire size, the wire length, and
the current supplied to the motors. Figure A-1 in the back of this manual shows the relationship
between the controller output voltage and load current.
The following tables show the separation between the controller and the antenna which will result in 22
and 18 volts being applied to the antenna drive motors as a function of motor current and wire gauge.
The tables take into account the controller output loading and resistive losses in the conductors.
Separation (in feet) between controller and antenna which will result in 28 volts being applied to the
motors:
Motor
Current
2 Amps
3 Amps
4 Amps
6 Amps
8 Amps
Separation (in feet) between controller and antenna which will result in 18 volts being applied to the
motors:
Motor
Current
2 Amps
3 Amps
4 Amps
6 Amps
8 Amps
10 Amps
A typical 36 volt actuator will draw 2 to 4 amps and will run at voltages down to about 12 volts.
Research Concepts, Inc. • 5420 Martindale Road • Shawnee, Kansas • 66218-9680 • USA
Chapter 3

Mechanical and Electrical Installation

16
14
1100
1744
611
968
366
581
122
193
45
72
16
14
1589
2519
937
1484
611
968
285
449
168
266
97
155
Installation
12
10
2777
4411
1543
2402
925
1470
308
490
115
183
12
10
4012
6372
2364
3754
1543
2450
716
1137
246
392
246
392