RC2000A Dual Axis Antenna Controller
ROTATING FEED PRESENT?:1
O-NO 1-YES
POL CONTROL? 0-NONE,1-ONE PORT:_
2-TWO PORT,3-POLAROTOR ENT,BKSP,SCRLL ^v
The Pol Angle Display CONFIG mode item determines the display format of polarization positions when
one of the motorized feed options is installed in the controller. If this item is enabled the polarization
position will be displayed in an angle format.
POL ANGLE DISPLAY:0
0-DISABLE, 1-ENABLE
When the Pol Angle Display item is enabled, the calibration of the angle display feature is controlled by
the Pol Display 0 Deg Cnt and Pol Display 90 Deg Cnt items. When the polarization position is equal to
the value which is entered for the Pol Display 0 Deg Cnt item, the angle displayed will 0.0. In a similar
fashion, when the polarization position is equal to the value, which is entered for the Pol Display 90 Deg
Cnt, the displayed angle will be 90.0. All other polarization positions are scaled in a linear fashion.
POL DISPLAY 0 DEG CNT: 500
1-1023
POL DISPLAY 90 DEG CNT: 750
1-1023
The Pol Motor Jog Duration CONFIG mode item controls the length of time (in milliseconds) that the
polarization motor drive signals are applied when a polarization jog command is received via the serial
communications port. The setting of this parameter determines the accuracy with which the polarization
can be adjusted via remote control.
POL MOTOR JOG DURATION:1000
175-3000 MSEC
The Pol CCW Limit CONFIG mode item controls the position count of the polarization CCW limit.
POL CCW LIMIT (0-1023):_800
CCW_LIM > CW_LIM !!
The Pol CW Limit CONFIG mode item controls the position count of the polarization CW limit.
POL CW LIMIT (0-1023):_200
CW_LIM > CW_LIM !!
4.10.8

Azimuth and Elevation Drive Options

The CONFIG mode items described in this section set the movement parameters for the azimuth and
elevation axis. The default values of these parameters (as initialized upon system reset) are adequate
for use with 36 volt linear actuators. For systems employing linear actuators, it is recommended that
Research Concepts, Inc. • 5420 Martindale Road • Shawnee, Kansas • 66218-9680 • USA
Chapter 4
CONFIG
ENT,BKSP,SCRLL ^v
CONFIG
CONFIG
ENT,BKSP,SCRLL ^v
CONFIG
ENT,BKSP,SCRLL ^v
CONFIG
ENT,BKSP,SCRLL ^v
CONFIG
ENT,BKSP,SCRLL ^v
CONFIG
ENT,BKSP,SCRLL ^v
CONFIG
ENT,BKSP,SCRLL ^v
Modes
www.researchconcepts.com

Advertisement

Table of Contents
loading

Table of Contents